Use and Care Manual

Remote controller cord
For extensions, a 26' cord can be purchased (Part # R C - C ORD26) or use 18AWG wire.
• Install according to the National Electrical Code and all applicable local codes.
Connecting Remote Controller Cord to Unit
Keep the remote controller cord away from the freeze prevention heaters in the unit.
Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment.
The remote controller cord can be extended up to 300' with 18AWG wire.
Use a Y type terminal with a resin sleeve. (Without the sleeve, the copper wire may corrode and
cause problems).
Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to the
terminal block.
1. Check to make sure that the remote controller cord
has plenty of slack in order to reach the ext er nal
connection terminal block.
2. Disconnect electrical power to the water heater.
3. Remove the single screw securing the terminal
block cover and then remove the cover.
4. Pass the remote contr o ller cord through the wir ing
throughway and connect the Y terminals at the end
of the remote controller cord to the terminal block.
5. Re place the terminal block cover and install the
screw previously removed in step 3.
6. Reconnect electrical power to the water heater.
External connection
terminal block
Wiring throughway
Remote controller cord

Summary of content (1 pages)