Use and Care Manual

Rev. 6/20/14
INSTALLATION INSTRUCTIONS for VK3-PVC-VAS
(Vertical Adapter Set for 3 PVC Concentric Termination)
*Not approved for Canada
Failure to follow the installation instructions could cause FIRE, CARBON MONOXIDE POISONING, or DEATH.
- It is recommended that experienced professionals familiar with the operation and maintenance of gas burning appliances and
vent/air intake systems install this system. These instructions are a guide to assist a professional installer.
- Before commencing installation, please read the installation instructions carefully.
- Failure to follow the installation instructions could cause not only lower performance of the appliance but also property damage
and/or personal injury.
- Please use only with Noritz condensing water heaters with a max exhaust temperature of 230°F.
- Please do not attempt to clean using any detergents which may cause deterioration.
- Examine all components for possible shipping damage prior to installation.
1. Kit Contents:
2. Separation Distance:
(1) Separation between intake and exhaust -
Do not cut the Adapter to ensure the proper separation distance between the VK3-H-PVC and Rain Cap.
(2) Separation from the roof -
Caution
Warning
!
!
Fig. 1 Adapter
Fig. 2 Rain Cap
U.S.: 12in (30cm)