User's Manual

Page 44
Norsat ODU 090-25012-00 Norsat
Cable By-pass
Procedures
Each of the three co-axial cables in the IFL are of identical cable
types, 50 ohm Belden 9907 with N(m) connectors, and can be
substituted for each other.
For alignment of the antenna, the
GREEN marked Receive IF coaxial
cable must be correctly connected as described earlier. However, the
RED and BLUE marked coaxial cables need not be attached.
For transmission, the
RED marked Transmit IF coaxial cable must be
correctly connected as described in earlier. However, the
GREEN and
BLUE marked coaxial cables need not be attached.
The
BLUE marked Transmit monitor coaxial cable is only required for
the Local Loopback and for monitoring the transmit spectrum on the
Spectrum Analyzer.
Receive IF Cable By-
pass
If the GREEN marked Receive IF coaxial cable is damaged, antenna
alignment can be done by substituting the
BLUE marked Transmit
Monitor cable or the
RED marked Transmit IF cable.
CAUTION
The cable interchange should be done with the power OFF as all
cables carry 24 V DC.
1. Disconnect both ends of the
GREEN marked Receive IF coaxial
cable.
2. To replace with the:
i.
RED marked Transmit IF coaxial cable, connect it in place of
the
GREEN marked Receive IF coaxial cable.
ii.
BLUE marked Transmit Monitor coaxial cable, connect it in
place of the
GREEN marked Receive IF coaxial cable.
3. Ensure that both ends of the replacement cable are connected to
the appropriate RX connectors on the Baseband IF and Antenna
RF units.
NOTE
Cable disconnection may result in alarms.