TYPE SS-R
Power Supply 24vDC
Power Consumption 2VA / 2W
Contacts Arrangements: 2 x N/O Safety Contacts; 1 x N/C Auxiliary Contact
Safety Contact Rating AC 230Vac / 2A
DC 24Vdc / 2A
Auxiliary Contact Rating AC 230Vac / 2A
DC 24Vdc / 2A
Contact Operating Distance 8mm ON / 10mm OFF
External Fuse (Customer Supplied) AC / DC 3 Amps Fast Acting
IP Rating IP67
Vibration / Shock 50—100Hz / 10g
Operating Temperature -10 to +55C
Mounting & Fixture Target to Target
Connection Pre-wired
Cable length Max 100 metres
Construction Blue ABS Resin Filled
TECHNICAL SPECIFICATION
SPECIFICATION CHANGES