Safety Switches User Manual
This information is designed to help suitably qualified
personnel install and operate Mechan Safety Switch
equipment. Before using this product, read this guide
thoroughly along with any relevant European and/or National
standards e.g. Machinery Directive 89/392/EEC and it’s
amendments, Provision and Use of Work Equipment
Regulations.
Further information can be obtained from
Mechan Controls
MAGNASAFE SS-C safety switches are electronically
operated non-contact safety switch for use in machine
guarding applications.
The non-contact operation makes the SS-C easy to install
and tolerant to misalignment, providing a simple reliable
solution to machine guard interlocking.
The electronic switching provides additional security and a
single point switching, leading to a more reliable and secure
long term switching solution. The switch and actuator are
IP67 rated and can be used in wet or dusty environments.
CE Complies with the relevant sections of the CE
marking directive.
UL Pending UL 508 Industrial Control Equipment
EUROPEAN DIRECTIVES
Machinery Directive 98/37/EC
Low Voltage Directive 73/23/EC
Electromagnetic Compatibility Directive 89/336/EC
EUROPEAN STANDARDS
EN292 Safety of Machinery
Basic concepts, general principles for design.
EN 60204 Safety of Machinery
Electrical equipment of machines.
EN 954-1 Safety of Machinery
Safety related parts of controls systems
EN 1088 Interlocking devices associated with guards.
EN
60947-5-3
Safety of Machinery
Specification for low voltage switchgear and
control gear.
Interlocked guards where additional security required.
Door locking is not required.
Food and Beverage packing/filling systems
Diary Pharmaceutical Paper Industry
Can Forming and Filling, (Aluminum, Steel, Plastic)
Semiconductor Manufacture/Assembly.
Description
A Declaration of Conformity may be obtained from Mechan
Controls PLC, Tel +44(0)1695 722264
or from the Mechan Web Site at www. mechancontrols.co.uk
Thee SSC is designed for use with ‘low inrush current’ safety
relays, maximum switching for long life performance is
500mA.
When installed on a machine guard, power is applied, and
the switch and actuator are within the specified operating
range (See table on page 4 for switching distances). The
Safety Contact will be closed and the Auxiliary Contact will
be open. The dual colour LED will be GREEN.
When the actuator moves out of the operating range, the
Safety Contact will open the Auxiliary Contact will close for
indication. The dual colour LED will be RED.
The SS-C safety switch and actuator have a 10mm switching
distance can approach each other from most angles. When
the switch is closed the targets on the printed face of the
switch must be aligned. To avoid physical damage, do not
use the switch and actuator as a stop, set a 2 mm gap for
best operation and tolerance to machine guard vibration.
Operation
KEEP THIS GUIDE FOR FUTURE REFERENCE
Applications
Approvals
Declaration of Conformity
MECHAN CONTROLS PLC
SS-C Safety Switch
Installation Guide
SS-C
Pending