3. If no movement detected in three minutes (default is 3 minutes - based on users
configuration setting, refer Table 1 (Parameter 5) will send Basic Set OFF (0x00), Red
LED will flash once, and refer to table for status.
4. The M360PIRZ-1 sensor equipped with tamper switch. If the tamper switch is triggered
(or remove the cover), the M360PIRZ-1 sensor will send Alarm Report, LED will flash
once and refer to table for status.
5. If the tamper switch is closed (or closed the cover), M360PIRZ-1 will send Alarm
Report,
and refer to table for status.
Alarm V1
(Movement & Tamper
Switch)
Notification V4
(Movement)
Notification V4
(Tamper Switch)
Alarm Type 0x07
Alarm Level
0x00 (No movement
after 3 mins)
0xFF (Motion
detected)
Notification Type
0x07 0x07
Notification
Event
0x08(Motion
Detected)/
0x00 (no movement
after 3 mins)
0x03(remove cover)/
0x00 (cover closed)
Notification
Event Parameter
0x08
0x03
6. Support OTA Firmware update from controller. Please refer to your controller manual
and use COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2. To proceed the OTA