Communication Server Large System Installation and Commissioning

Page 160 of 456 Configuring the system monitor
NN43021-310 Standard 02.01 December 2007
Figure 65
Cabling CS 1000M SG or Meridian 1 PBX 61C, single column with
stacked Core/Net modules – cable master system monitor to SDI port
5 Daisy-chain slave system monitors to the master.
a. For a single-column system, skip this step.
b. For a multiple-column system, beginning with the master system
monitor, cable in series (slave 1 to slave 2, slave 2 to slave 3, and so
on) from connector J6 to connector J5 on each system monitor (see
Figure 66 on page 161). Terminate at connector J5 on the last
column.
If columns are adjacent, use an NT8D46AL cable.
If columns are not adjacent, use an NT8D46AP cable.
553-3111
NT8D46AA
J1
To SDI port To next module
Backplane
CPU 0
To system monitor/
power supply assembly
in the pedestal
J2
NT8D46AG