Communication Server Large System Installation and Commissioning
Configuring the system monitor Page 161 of 456
Communication Server 1000M and Meridian 1 Large System Installation and Commissioning
Figure 66
Multiple-column system monitor connections
6 For PFTU or external alarm cabling, connect a system monitor to MDF
cable.
• Connect a system monitor to MDF cable to connector J3 on the
master system monitor.
• Connect the cable at the alarm termination area at the MDF. See
Table 12 for the terminating sequence.
J3 J5
J6
J4
J3 J5
J6
J4
Column 0
Master system monitor
Slave unit n
Slave unit 1
From J6 of previous
system monitor
(NT8D46AL/AP cable)
To J5 of next
slave system monitor
(NT8D46AL/AP cable)
553-3114
J3 J5
J6
J4
From J6
on master
To J5
on slave 1
Terminate on J5
of last column in series
From J6 to
J5 on slave 2
NT8D46BH alarm cable
to MDF
Cable to external
power equipment
J3 J5
J6
J4