Table 37
NT8D37 IPE Module: NT8D14 Universal Trunk Card pair-terminations
Lead designations
Pin
numbers Pair color Unit
RAN
mode
Paging
mode
Other
modes
0T/0R
CP/MB
0T/0R
A/PG
0T/0R 26/1
27/2
W-BL/BL-W
W-O/O-W
0
1T/1R
CP/MB
1T/1R
A/PG
1T/1R 28/3
29/4
W-G/G-W
W-BR/BR-W
1
2T/2R
CP/MB
2T/2R
A/PG
2T/2R 30/5
31/6
W-S/S-W
R-BL/BL-R
2
3T/3R
CP/MB
3T/3R
A/PG
3T/3R 32/7
33/8
R-O/O-R
R-G/G-R
3
4T/4R
CP/MB
4T/4R
A/PG
4T/4R 34/9
35/10
R-BR/BR-R
R-S/S-R
4
5T/5R
CP/MB
5T/5R
A/PG
5T/5R 36/11
37/12
BK-BL/BL-BK
BK-O/O-BK
5
6T/6R
CP/MB
6T/6R
A/PG
6T/6R 38/13
39/14
BK-G/G-BK
BK-BR/BK-BR
6
7T/7R
CP/MB
7T/7R
A/PG
7T/7R 40/15
41/16
BK-S/S-BK
Y- B L / B L - Y
7
Note 1: Each of the following I/O panel connectors is cabled as shown
above: connectors A, B, C, D, E, F, G, H, K, L, M, N, R, S, T, and U. These
connectors are associated with backplane slots 0 through 15, sequentially.
Note 2: Use LD 14 to select trunk termination impedance (600 ohm or
900 ohm). See the Software Input/Output: Administration (NN43001-611)