Communication Server Large System Installation and Commissioning
Page 330 of 456 Powering up the system and initial loading
NN43021-310 Standard 02.01 December 2007
At this point the system should reload and initialize.
End of Procedure
Testing Core/Net 1 and Core/Net 0
LD 137 modifications
The
CMDU/MMDU commands are not applicable to CP PIV. Instead, the
following commands are introduced in LD 137.
•
STAT FMD
display text: Status of both Fixed Media Devices (FMD)
command parameter: none
•
STAT FMD 0/1
display text: Status of the specified Fixed Media
Device
command parameter: “core #” with values of 0 or 1
•
STAT RMD
display text: Status of both Removable Media Devices
(RMD)
command parameter: none
•
STAT RMD
display text: Status of the specified Removable Media
Device
command parameter: “core #” with values of 0 or 1
Procedure 56
Testing Core/Net 1
1 Perform a redundancy sanity test:
2 Check the LCD states:
LD 135 Load program
STAT CPU Get status of CPU and memory
TEST CPU Test CPU