Communication Server Large System Installation and Commissioning
Page 56 of 456 Preparing for installation
NN43021-310 Standard 02.01 December 2007
Since all faceplate to I/O panel cables are the same length and card positions
in the card cage vary, a cable can contain excess slack. It is therefore
recommended that cables from cards in the left side of the card cage use the
right I/O panel and cables from cards in the right side of the card cage use the
left I/O panel whenever possible, as shown in Figure 13.
Figure 13
Top view of front to I/O connector panel routing
As space permits, cables can be routed:
1 Horizontally in the cable troughs at the front, rear, and sides of the
module
Note: In a DC-powered module, because there is no MPDU, there is
room to route cables horizontally from front to rear on the left side (front
view) of the module.
PS
This side uses right I/O Connector PanelThis side uses left I/O Connector Panel
Left I/O Connector Panel
I/O Panel
Card Cage
Right I/O Connector Panel
553-749
6