Water System User Manual

108 Chapter 5 Creating and managing VLANs
214393-A
Accepting untagged frames
In the BayStack 380-24F, you configure whether or not untagged frames are sent
or received on the port level. Refer to “VLAN tab for a single port” on page 78 for
VLAN tab field descriptions. You can select whether or not to discard untagged
frames received on a port:
The default is not to discard the untagged frames. You can also designate the
port-based VLAN to which these frames are assigned by setting the untagged
port’s default VID (the default is 1).
To set a port to discard untagged frames it receives:
1 In the Device Manager main window, select a port.
2 From the Device Manager menu bar, choose Edit > Port.
The Port dialog box opens with the Interface tab displayed (Figure 35 on
page 76).
3 Click the VLAN tab.
The VLAN tab opens (Figure 50).
Figure 50 VLAN tab
Select the DiscardTaggedFrames and the DiscardUntaggFrames check boxes.
4 Click Apply.