User Guide

30 Chapter 1 Installing the Nortel VPN Router 2750 chassis
NN46110-318 02.01
Installing the chassis in an equipment rack
To mount the VPN Router 2750 in an equipment rack, you need the following
equipment:
a standard 19-inch equipment rack
four screws (supplied with the chassis)
four cage nuts (supplied with the chassis) if the rack does not have threaded
rail holes
a #2 Phillips screwdriver
Rack-mount recommendations
When you mount the chassis in the equipment rack, observe the following
standard recommendations:
Nortel recommends a maximum ambient temperature of 40
o
C (104
o
F). Ensure
that the internal temperature of the rack does not exceed (104
o
F).
Do not block the power supply vents or otherwise restrict air flow when
installing the chassis in the rack.
Stabilize your rack so that it does not tip over under the weight of the gateway
and other devices.
Ensure that the electrical branch circuits can handle the VPN Router 2750 and
other units in the rack before you install and turn on the gateway.
Maintain a reliable earth-ground path in the rack system. You must connect
the gateway to an earth ground.
Attaching the shelf in the equipment rack
The VPN Router 2750 ships with a rack-mount shelf to support the chassis in the
equipment rack.
To attach the shelf to the inside of the equipment rack:
1 If the holes in the rack’s vertical supports are not threaded, attach a cage nut in
four locations at the front of the rack (Figure 3 on page 31).