Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules Release: 5.0 Document Revision: 01.01 www.nortel.com NN46205-316 .
Nortel Ethernet Routing Switch 8600 Release: 5.0 Publication: NN46205-316 Document status: Standard Document release date: 30 May 2008 Copyright © 2008 Nortel Networks All Rights Reserved. Printed in Canada, India and the United States of America LEGAL NOTICE While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS OR IMPLIED.
. Contents Regulatory Information and Safety Precautions 5 Software license 17 New in this release 21 Features 21 Other changes 21 Document changes 21 Introduction 23 MDA overview 25 Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules 27 Estimated installation time 27 Estimated time for installation 27 Translation of Safety messages Class A product caution statement 38 MDA and LED specifications Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adap
Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. Regulatory Information and Safety Precautions Read the information in this section to learn about regulatory conformities and compliances.
Regulatory Information and Safety Precautions ICES Statement (Canada only) Canadian Department of Communications Radio Interference Regulations This digital apparatus (8000 Series chassis and installed components) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
National Electromagnetic Compliance (EMC) Statements of Compliance 7 European Union and European Free Trade Association (EFTA) Notice All products labeled with the CE marking comply with R&TTE Directive (1999/5/EEC) which includes the Electromagnetic Compliance (EMC) Directive (2004/108/EC) and the Low Voltage Directive (2006/95/EC) issued by the Commission of the European Community. Compliance with these directives implies conformity to the following European Norms (ENs).
Regulatory Information and Safety Precautions National Safety Statements of Compliance CE Marking Statement (Europe only) EN 60 950 Statement This is to certify that the Nortel 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
National Safety Statements of Compliance 9 México D.F. 03900 Tel: 52 5 480 2100 Fax: 52 5 480 2199 Input: Model 8003AC: 100-240 VAC, 50-60 Hz, 9 A maximum for each power supply Model 8004AC: 100-240 VAC, 50-60 Hz, 12-6 A maximum for each power supply Model 8005AC: 100-120 VAC, 50-60 Hz, 16 A maximum for each power supply 200-240 VAC, 50-60 Hz, 8.5 A maximum for each power supply Model 8005DI AC: 100-120 VAC, 50-60 Hz, 16 A maximum for each power supply 200-240 VAC, 50-60 Hz, 9.
Regulatory Information and Safety Precautions Col. San Jose Insurgentes Deleg-Benito Juarez México D.F. 03900 Tel: 52 5 480 2100 Fax: 52 5 480 2199 Embarcar a: Model 8003AC: 100-240 VCA, 50-60 Hz, 9 A max. por fuente de poder Model 8004AC: 100-240 VCA, 50-60 Hz, 12-6 A max. por fuente de poder Model 8005AC: 100-120 VCA, 50-60 Hz, 16 A max. por fuente de poder 200-240 VCA, 50-60 Hz, 9.5 A max.
Safety Messages 11 Safety Messages This section describes the different precautionary notices used in this document. This section also contains precautionary notices that you must read for safe operation of the Nortel Ethernet Routing Switch 8600. Notices Notice paragraphs alert you about issues that require your attention. The following sections describe the types of notices. For a list of safety messages used in this guide and their translations, see "Translations of safety messages".
Regulatory Information and Safety Precautions CAUTION ATTENZIONE ESD Le indicazioni ESD forniscono informazioni per evitare scariche di elettricità statica e i danni correlati per i prodotti Nortel. Caution Notice CAUTION Caution notices provide information about how to avoid possible service disruption or damage to Nortel products.
Safety Messages 13 WARNING AVERTISSEMENT La mention Avertissement fournit des informations sur les moyens de prévenir les risques de blessure lors de la manipulation de produits Nortel. WARNING WARNUNG Warnhinweise bieten Informationen dazu, wie man Personenschäden bei der Arbeit mit Nortel-Produkten verhindert. WARNING ADVERTENCIA Los avisos de Advertencia brindan información acerca de cómo prevenir las lesiones a personas al trabajar con productos Nortel.
Regulatory Information and Safety Precautions DANGER PELIGRO Los avisos de Peligro-Alto voltaje brindan información acerca de cómo evitar una situación o condición que cause graves lesiones a personas o la muerte, a causa de una electrocución o de una descarga de alto voltaje. DANGER PERIGO Avisos de Perigo—Alta Tensão oferecem informações sobre como evitar uma situação ou condição que possa causar graves ferimentos ou morte devido a alta tensão ou choques elétricos.
Safety Messages DANGER PERICOLO Le indicazioni di pericolo forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso. Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
Regulatory Information and Safety Precautions Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. Software license This section contains the Nortel Networks software license. Nortel Networks Inc. software license agreement This Software License Agreement ("License Agreement") is between you, the end-user ("Customer") and Nortel Networks Corporation and its subsidiaries and affiliates ("Nortel Networks"). PLEASE READ THE FOLLOWING CAREFULLY. YOU MUST ACCEPT THESE LICENSE TERMS IN ORDER TO DOWNLOAD AND/OR USE THE SOFTWARE. USE OF THE SOFTWARE CONSTITUTES YOUR ACCEPTANCE OF THIS LICENSE AGREEMENT.
Software license of this Agreement. Customer shall not a) use, copy, modify, transfer or distribute the Software except as expressly authorized; b) reverse assemble, reverse compile, reverse engineer or otherwise translate the Software; c) create derivative works or modifications unless expressly authorized; or d) sublicense, rent or lease the Software. Licensors of intellectual property to Nortel Networks are beneficiaries of this provision.
Nortel Networks Inc. software license agreement 19 software documentation and, in the event Software is licensed for or on behalf of the United States Government, the respective rights to the software and software documentation are governed by Nortel Networks standard commercial license in accordance with U.S. Federal Regulations at 48 C.F.R. Sections 12.212 (for non-DoD entities) and 48 C.F.R. 227.7202 (for DoD entities). 2. Customer may terminate the license at any time.
Software license Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. New in this release The following sections detail what’s new in Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules, NN46205-316 for release 5.0. • • “Features” (page 21) “Other changes” (page 21) Features This document contains no feature updates in release 5.0 .
New in this release Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. Introduction This guide describes how to install the Media Dependent Adapters (MDAs) for the 8672ATME and 8672ATMM Modules on Ethernet Routing Switch 8600. Navigation • • “MDA overview” (page 25) • “MDA and LED specifications” (page 41) “Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules ” (page 27) Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.
Introduction Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. MDA overview The MDAs for the Nortel 8672ATME and 8672ATMM modules are modular port adapters that are installed on the Ethernet Routing Switch 8600. The 8672 ATM modules are part of the Nortel 8000 Series line of communications products. There are two versions of the ATM modules: the 8672ATME module and the 8672ATMM module (unless otherwise specified, the term 8672ATM modules refers to both versions). Each module has two slots for MDAs.
MDA overview Figure 3 DS-3 MDA: 8672ATME and 8672ATMM modules Each MDA has ports for connection to an ATM network. OC-3c/STM-1 and OC-12c/STM-4 MDAs support concatenated transmission. The flexibility of connectivity is achieved by mixing different types of MDAs. The following table shows the available types of MDAs for the 8672ATME and 8672ATMM modules.
. Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules This section provides procedures for installing MDA for the 8672ATME and 8672ATMM modules.
Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules Table 2 Task and estimated time (cont’d.) Task Estimated time Aligning the MDA with the front portion of the module and mounting the posts 2–5 minutes Seating MDA and tightening the screws and the label 2–5 minutes Removing dust plugs and caps 2–5 minutes Total time required 10–22 minutes Installing an MDA This procedure describes how to install an MDA on Ethernet Routing Switch 8600.
Installing an MDA 3 Line up the MDA with the front of the 8672ATME or the 8672ATMM module, positioning the MDA so that the front aligns with the front of the 8672ATME or the 8672ATMM module. 4 Align the four holes on the MDA with the mounting posts on the 8672ATME or the 8672ATMM module. 5 Press firmly on the MDA in the middle of the back to seat the MDA in the mounting posts on the module. Apply about 20 pounds of pressure.
Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules 7 Attach the supplied laser product label to the front panel of the host module immediately below the MDA. Use the label that is printed in the appropriate language for the country where you are installing the equipment. --End-- Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
Replacing an MDA 31 Replacing an MDA This procedure describes how to replace an MDA. CAUTION Risk of service loss You cannot hot-swap an MDA. You must remove the 8672ATME or 8672ATMM module, install the MDA, and then reinstall the module. Procedure steps Step Action 1 Remove the 8672ATME or the 8672ATMM module from the chassis and lay it on a flat, static-free surface. For information about removing a module from the chassis, see Ethernet Routing Switch 8600 Installation — Modules, NN46205-304.
Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules 5 If you do not plan to install a replacement MDA, place the slot cover on the MDA slot and tighten the two screws. --End-- Connecting fiber cables This procedure describes how to connect fiber cables to the installed MDA. The OC-12c/STM-4 MDA uses duplex SC connectors. See Figure 5 "OC-12c/STM-4 MDA duplex SC connector with dust caps" (page 32). Also, the OC-3c/STM-1 MDA uses MT-RJ connectors.
Connecting fiber cables 2 Remove the protective dust caps from the connector on the fiber cable. Store the dust caps for later use. 3 Hold the fiber cable connector so the keyed surface will insert easily into the MDA connector. Carefully insert the cable connector into the MDA connector and push gently. Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules --End-- Connecting coaxial cables This procedure describes how to connect coaxial cables to the MDA. ATTENTION The DS-3 MDA uses bayonet Neill-Concelman (BNC) connectors. Procedure steps Step Action 1 Push the coaxial cable onto the DS-3 connector. Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.
Connecting coaxial cables 2 Turn the coaxial cable to the right until the key on the DS-3 connector clicks into the notch on the coaxial cable. --End-- Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
Media Dependent Adapter installation for the 8672ATME and 8672ATMM modules Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. Translation of Safety messages Class A product caution statement CAUTION This device is a Class A product. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users are required to take appropriate measures necessary to correct the interference at their own expense. CAUTION ATTENTION Le périphérique est un produit de Classe A.
Translation of Safety messages CAUTION CUIDADO Este dispositivo é um produto Classe A. Operar este equipamento em uma área residencial provavelmente causará interferência prejudicial; neste caso, espera-se que os usuários tomem as medidas necessárias para corrigir a interferência por sua própria conta. CAUTION ATTENZIONE Questo dispositivo è un prodotto di Classe A.
CAUTION CAUTION CUIDADO ESD Para evitar danos com descarga eletrostática, sempre use uma pulseira antiestática que esteja conectada a uma tomada de descarga eletrostática (ESD) quando estiver realizando a manutenção deste produto. Certifique-se de que a pulseira esteja em contato com sua pele. CAUTION ATTENZIONE ESD Per evitare danni derivanti da scariche elettrostatiche, indossare sempre un polsino antistatico collegato a una presa di scarico elettrostatico (ESD) durante la manutenzione del prodotto.
Translation of Safety messages Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
. Appendix MDA and LED specifications See the following sections for Media Dependent Adapters (MDAs) and Light Emitting Diode (LED) specifications. MDA specifications The OC-3c/STM-1 MDA uses SONET STS-3c/SDH STM-1 1300 nanometer (nm) optical transceivers with MT-RJ fiber-optic connectors and either single mode fiber (SMF) or multimode fiber (MMF) cabling. The following table describes the 8672ATME and 8672ATMM modules MDA specifications of OC-12c/STM-1 and OC-3c/STM-4 port type.
MDA and LED specifications Table 4 OC-3c/STM-1 MDA specifications: 8672ATME and 8672ATMM modules (cont’d.) Parameter SMF description MMF description Distance 15 km 2 km Input power 40 W 40 W Thermal rating 138 BTU/hour maximum 138 BTU/hour maximum The OC-12c/STM-4 MDA uses SONET STS-3c/SDH STM-1 1300 nm optical transceivers with duplex SC-type fiber-optic connectors and either single mode fiber (SMF) or multimode fiber (MMF) cabling.
LEDs 43 Table 7 MDA LED indications Label Color State Meaning TX Green Steady Indicates network activity for the corresponding port. A very low level of network activity (approximately 1–5 pps) can cause the LED to blink. — Off The port is not transmitting data (no network activity). Amber Blinking The port is out of order; the administrative state is down. Green Blinking Indicates network activity for the corresponding port (the port is receiving traffic).
MDA and LED specifications Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules NN46205-316 01.01 Standard 30 May 2008 Copyright © 2008 Nortel Networks .
Nortel Ethernet Routing Switch 8600 Installation — Media Dependent Adapters for the 8672ATME and 8672ATMM Modules Copyright © 2008 Nortel Networks All Rights Reserved. Printed in Canada, India and the United States of America Release: 5.0 Publication: NN46205-316 Document status: Standard Document revision: 01.01 Document release date: 30 May 2008 To provide feedback or to report a problem in this document, go to www.nortel.com/documentfeedback. www.nortel.