CTR 28 GHz Release 1.2 1-21
Reunion CTR 28 GHz Installation Guide
CTR 28 GHz Diagnostic Reference Chart
Symptom Possible Cause Check Procedure
Output power low 1. VHF input signal level low. a. Check VHF signal level.
b. Check coaxial cable.
c. Check cable connectors.
d. Check antenna for blockage (e.g. guano)
No power a. check main fuse power
b. check cable connections
If you detect any problem during the electrical and mechanical checks, contact Nortel Networks
Broadband Wireless Access so that action can be taken to rectify the problem.
Caution
Warranty void if seal is opened. This means do not
attempt to remove cover.
Caution
Warranty void if CTR is not equipped with