Server User's Manual

Configure the NT5D97 DDP2 141
Procedure 15
Remove the NT5D97 from Large Systems
Step Action
1
Determine the cabinet and shelf location of the NT5D97 card to
be removed.
2
Disable the Network Loop using LD 60. The command is DISL
"loop number."
The associated DCHI might have to be disabled first. The faceplate
switch ENB/DIS should not be disabled until both PRI2/DTI2 loops
are disabled first.
3
Remove data from memory, if the NT5D97 card is being completely
removed, not replaced.
4
Remove cross connections at the MDF to wall-mounted crossconnect
terminal.
5
Tag and disconnect cables from the card.
6
Rearrange Clock Controller cables if required.
CAUTION
Clock Controller cables connecting the Clock Controller
and DDP2 card must NOT be routed through the center of
the cabinet past the power harness. Instead, they should
be routed around the outside of the equipment shelves.
7
Remove the DDP2 card only if both loops are disabled. If the other
circuit of a DDP2 card is in use, DO NOT remove the card. The
Faceplate switch ENB/DIS must be in the OFF (DIS) position before
the card is removed, otherwise the system will initialize.
8
Pack and store the NT5D97 card and circuit card.
—End—
Configure the NT5D97 DDP2
After the NT5D97 DDP2 is installed, configure the system using the same
procedures as the standard NT8D72BA PRI2.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
Copyright © 2003-2007, Nortel Networks
.