Server User's Manual

Table Of Contents
IP Phone passwords and parameters 217
1
Configure the length of the password, SCPL, to be of non-zero
length in LD 15.
LD 15 Configure the SCPW length in the Customer Data Block.
Prompt Response Description
REQ: CHG Change existing data.
TYPE: FFC Flexible Feature Code
SCPL
0-8
Length of SCPW, minimum recommended is 4 digits
2
Assign the Automatic Set Relocation security code.
LD 15 Assign Automatic Set Relocation security code.
Prompt Response Description
REQ: CHG Change existing data.
TYPE: FTR Customer Features and options
CUST Customer number
0-99
Range for Large System and CS 1000E system
0-31
Range for Small System and Media Gateway 1000B
SRCD (0000)-9999 Automatic Set Relocation security code X removes
security code
3
Configure the Flexible Feature Code in LD 57 to enable Station
Control Password Change (SCPC) and Set-Based Removal if
desired.
LD 57 Enable password change and set removal features.
Prompt Response Description
REQ NEW Add new data.
TYPE FFC Flexible Feature Code
CUST
xx
Customer number as defined in LD 15
FFCT YES Flexible Feature Confirmation Tone
CODE AREM Automatic Set Removal
- AREM
xxxx
Code to invoke Automatic Set Removal
CODE SCPC Station Control Password Change
- SCPC
xxxx
Code to invoke password change
4
The SCPW itself is configured during IP Phone configuration, either
using TM 3.1 (see "MG 1000B IP Phone configuration using TM
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2007, Nortel Networks
.