Server User's Manual

Table Of Contents
Installing and configuring IP Phones 271
Main office password IP Phone Installer’s Password, Temporary IP
Phone Installer’s Password, or SCPW.
For information on setting up passwords, see "IP Phone passwords and
parameters" (page 215).
Branch User Config is used for configuration. Once the IP Phone is
configured at the Branch Office, its parameters redirect the IP Phone to the
main office. This means that configuration is not required a second time
unless the Branch User parameters change on that IP Phone.
Attempting to perform a Branch User Config to a TN of a different set type
at the main office results in a Permission Denied (4) error message on the
display of the IP Phone. See Table 26 "Normal Operation troubleshooting"
(page 349) for more information on error messages.
Whenever a valid change is made to BUID/MOTN in LD 11, the IP Phone,
if in Local Mode, is automatically redirected to the main office. A service
change to BUID/MOTN does not affect IP Phones in Normal Mode. If the
BUID of an IP Phone is deleted in a service change, no attempt is made to
redirect the telephone to the main office.
WARNING
Do not delete the BUID/MOTN. If they are subsequently deleted,
the association between the main office and the Branch Office
is lost, and any IP Phones which are in, or go into, Local Mode,
remain in Local Mode.
Procedure 25
Configuring a Branch User
Step Action
1
To invoke the login and configuration operation for a Branch User,
press the Services key (the key with the Globe icon) on an idle IP
Phone. If the Branch Office package is equipped, the Virtual Office
Login and Branch User Config options are displayed.
2
Select Branch User Config, as shown in Figure 100 "Options
menu" (page 270).
3
Enter the Branch User ID, that is a dialable DN of the main office.
See Figure 101 "Branch User ID" (page 272).
For a CDP dialing plan, the Access Code is not required. For
example, xxx-xxxx. For a UDP dialing plan, this DN includes the
Access Code. For example, 6-xxx-xxxx.
Nortel Communication Server 1000
Branch Office Installation and Commissioning
NN43001-314 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2007, Nortel Networks
.