Switch User Manual

126 IP Routing Configuration and Management
Step Action
1
Configure tagging on ports 1/47 and 1/48. Tagging is required to
support multiple VLANs on the same interface.
5530-24TFD# enable
5530-24TFD# config terminal
5530-24TFD(config)# vlan ports 1/47-48 tagging tagAll
2
Configure ERS2 for VLAN 2 access.
a. Create a port-based VLAN (VLAN 2) using spanning tree group
1 and include ports 1/47 and 1/48 in VLAN 2.
5530-24TFD(config)# vlan create 2 name "VLAN-2" type
port
5530-24TFD(config)# vlan member add 2 port 1/47-48
b. Assign the IP address 10.1.20.2/24 to VLAN 2.
5530-24TFD(config)# interface vlan 2
5530-24TFD(config-if)# ip address 10.1.20.2
255.255.255.0
c. Enable RIP for VLAN 2 and disable RIP supply and listen. RIP
supply and listen are not required because no router is attached
to VLAN 2.
5530-24TFD(config)# interface vlan 2
5530-24TFD(config-if)# ip rip enable
5530-24TFD(config-if)# ip rip supply disable
5530-24TFD(config-if)# ip rip listen disable
3
Configure ERS2 for VLAN 3 access.
a. Create a port-based VLAN (VLAN 3) using spanning tree group
1 and include ports 1/47 and 1/48 in VLAN3.
5530-24TFD(config)# vlan create 3 name "VLAN-3" type
port
5530-24TFD(config)# vlan member add 3 port 1/47-48
b. Assign the IP address 10.1.30.2/24 to VLAN 3.
5530-24TFD(config)# interface vlan 3
5530-24TFD(config-if)# ip address 10.1.30.2
255.255.255.0
c. Enable RIP for VLAN 3 and disable RIP supply and listen. RIP
supply and listen are not required because no router is attached
to VLAN 3.
5530-24TFD(config)# interface vlan 3
5530-24TFD(config-if)# ip rip enable
5530-24TFD(config-if)# ip rip supply disable
Nortel Ethernet Routing Switch 5500 Series
Configuration-IP Routing Protocols
NN47200-503 03.01 Standard
5.1 27 August 2007