Switch User Manual
IP routing configuration examples 197
The Nortel Ethernet Routing Switch 5500 Series (E1), running in Layer 2
mode, is configured with one port-based VLAN and one MultiLink Tr unking
(MLT) group for the aggregate uplink ports. The Nortel Ethernet Routing
Switch 5500 Series switches (R1 and R2) are configured with backup
master enabled so that both switches can reply to ARP.
VRRP with SMLT configuration
The following procedure would be used to recreate the illustrated topology:
Step Action
1
Configure the IST VLAN on R1
a. Configure IST VLAN 3999 on R1
5530-24TFD# config terminal
5530-24TFD(config)# vlan create 3999 type port
5530-24TFD(config)# interface vlan 3999
5530-24TFD(config-if)# ip address 2.1.1.1
255.255.255.0
b. Configure IST MLT on R1
5530-24TFD# config terminal
5530-24TFD(config)# mlt 1 member 2/1-2/2
5530-24TFD(config)# vlan port 2/1-2/2 tagging enable
5530-24TFD(config)# mlt 1 enable
c. Configure the IST and add the IST to VLAN 3999
5530-24TFD# config terminal
5530-24TFD(config)# interface mlt 1
Nortel Ethernet Routing Switch 5500 Series
Configuration-IP Routing Protocols
NN47200-503 03.01 Standard
5.1 27 August 2007
Copyright © 2005-2007, Nortel Networks
.