Part No.
Copyright © 2001 Nortel Networks All rights reserved. April 2001. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks Inc.
SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. In addition, the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure (that may incorporate by reference certain limitations and notices imposed by third parties).
Japan/Nippon requirements only Voluntary Control Council for Interference (VCCI) statement Taiwan requirements Bureau of Standards, Metrology and Inspection (BSMI) statement Canada requirements only Canadian Department of Communications Radio Interference Regulations This digital apparatus Nortel Networks Contivity VPN Switch does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
purposes in support of authorized use of the Software; and c) to use and copy the associated user manual solely in support of authorized use of the Software by Licensee. This license applies to the Software only and does not extend to Nortel Networks Agent software or other Nortel Networks software products. Nortel Networks Agent software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel Networks Inc.
Government funds. The license to the U.S. Government is granted only with restricted rights, and use, duplication, or disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial Computer Software––Restricted Rights clause of FAR 52.227-19 and the limitations set out in this license for civilian agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS 252.
Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Memory option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Chapter 3 Contivity 2600 Option Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Opening the Contivity 2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figures Figure 1 Removing the Contivity 4500 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 2 Contivity 4500 front components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Figure 3 Sample Contivity 4500 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 4 Installing 4500 LAN/WAN and hardware accelerator option cards . . . . . . 25 Figure 5 Installing Contivity 4500 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figures Figure 31 Removing the system from the chassis . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Figure 32 Contivity 600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Figure 33 Replacing the system into the chassis . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface This document describes how Nortel Networks* trained service personnel can install or replace hardware components for models 4500, 4000, 2600, 2500, 2000, 1600, 1500, and 600 of the Contivity VPN Switch*.
Preface Documentation This document uses the following conventions to distinguish among notes of varying importance. Note: Take notice. Notes contain helpful suggestions or references to materials contained in this document. Caution: Be careful. In this situation, you might do something that could result in damage to the equipment or loss of data. Warning: Danger. You are in a situation that could cause bodily injury.
Preface 13 Text This guide uses the following text conventions: angle brackets (< >) Indicate that you choose the text to enter based on the description inside the brackets. Do not type the brackets when entering the command. Example: If the command syntax is ping , you enter ping 192.32.10.12 bold Courier text Indicates command names, options, and text that you need to enter. Example: Use the dinfo command. Example: Enter show ip {alerts|routes}.
Preface italic text Indicates new terms, book titles, and variables in command syntax descriptions. Where a variable is two or more words, the words are connected by an underscore. Example: If the command syntax is show at , valid_route is one variable and you substitute one value for it. plain Courier text Indicates command syntax and system output, for example, prompts and system messages. Example: Set Trap Monitor Filters separator ( -> ) Shows menu paths.
Preface 15 Acronyms This guide uses the following acronyms: AUI attachment unit interface BootP Bootstrap Protocol BRI basic rate interface CSMA/CD carrier sense multiple access/collision detection DLCMI Data Link Control Management Interface HDLC High-level Data Link Control IP Internet Protocol ISDN Integrated Services Digital Network ISO International Organization for Standardization ITU-T International Telecommunication Union-Telecommunication Standardization Sector (formerly CCITT)
Preface Hard-copy technical manuals You can print selected technical manuals and release notes free, directly from the Internet. Go to the www25.nortelnetworks.com/library/tpubs/ URL. Find the product for which you need documentation. Then locate the specific category and model or version for your hardware or software product. Use Adobe Acrobat* Reader to open the manuals and release notes, search for the sections you need, and print them on most standard printers. Go to Adobe Systems* at the www.adobe.
Preface 17 How to get help If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance.
Preface 302283-D Rev 00
Chapter 1 Contivity 4500 Option Installation This section describes how to install or replace hardware components for the Contivity 4500. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory.
Chapter 1 Contivity 4500 Option Installation 1 Insert a flat-head screwdriver into the slots on the lower left and right sides of the chassis, and pry the bezel forward. 2 Slide your fingers between the front bezel and the switch. 3 Pull the bezel forward firmly, separating the ball studs on the bezel from the sockets on the chassis. Figure 1 shows you how to remove the front bezel from the switch. You do not need to turn off the switch to remove the front bezel.
Chapter 1 Contivity 4500 Option Installation 21 Remove the Contivity 4500 front bezel to: • • • Replace a power supply. Replace a hard disk drive. Insert the recovery diskette. Figure 2 shows the Contivity 4500 front components. Figure 2 Contivity 4500 front components Disk drives 3.
Chapter 1 Contivity 4500 Option Installation Contivity 4500 system board layout This section describes installing option cards onto the system board. Warning: Only Nortel Networks trained service personnel should change existing hardware configurations. Improper handling of internal components or assemblies, with the power connected, could cause severe injury. Note: Wear an antistatic band when handling electronic components for the switch to avoid damaging them.
Chapter 1 Contivity 4500 Option Installation 23 Figure 3 shows the Contivity 4500 system board, in particular the DIMMs and option card slots.
Chapter 1 Contivity 4500 Option Installation Installing Contivity 4500 LAN/WAN and hardware accelerator option cards This section describes how you install option cards into the Contivity 4500 option card slide-out tray. The following procedure is for Nortel Networks trained service personnel only. 1 Turn off the switch and unplug both power cords from the power source. 2 Unscrew the four slotted thumb screws securing the slide-out tray. Pull out the tray by gripping it with the screws.
Chapter 1 Contivity 4500 Option Installation 25 Figure 4 shows you how to install LAN, WAN, or hardware accelerator option cards into the Contivity 4500. You can use the 6 slots for any mix of LAN and WAN or hardware accelerator cards; however, you must populate the slots from bottom to top, in that order.
Chapter 1 Contivity 4500 Option Installation Installing Contivity 4500 DIMMs Figure 5 shows you how to unlock a Dual Inline Memory Module (DIMM) in the Contivity 4500, and remove or install a DIMM. Install a DIMM in the next available slot (for example, if the DIMM #1 slot is populated, then add the next DIMM to the DIMM #2 slot).
Chapter 1 Contivity 4500 Option Installation 27 To install a DIMM into the Contivity 4500, follow these steps: 1 Turn off the switch. 2 Remove the power cords. 3 Unscrew the slide-out tray at the back of the unit and pull it out using the thumb screws. 4 Remove the support bracket by loosening the two secured captive screws and the rear Phillips screw. 5 Press down the locking levers on both sides of the next available DIMM slot to allow the new DIMM to be inserted.
Chapter 1 Contivity 4500 Option Installation Replacing a Contivity 4500 power supply Figure 6 shows you how to replace a hot-swappable power supply for the Contivity 4500. Figure 6 Removing a Contivity 4500 power supply Bo ot/ Ale Read rt/F y ail CS460010A To remove the power supply: 1 Remove the front bezel as shown in Figure 1. 2 Use a flat-head screwdriver to unscrew the top and bottom power supply screws. 3 Grab the handle and pull the power supply firmly, until the device disengages.
Chapter 1 Contivity 4500 Option Installation 29 4 Insert the new power supply. Make sure the power supply seats firmly in its socket and is locked in. Be sure the green power LED on the front of the power supply is on. 5 Secure the power supply screws tightly with a screwdriver. 6 Replace the front bezel.
Chapter 1 Contivity 4500 Option Installation Replacing a Contivity 4500 hard disk drive Warning: Contivity 4500 hard disks are not hot-swappable. When swapping a disk drive, you must first perform the steps listed below to ready the switch for the swap. This process is referred to as “warm-swapping” a disk drive. Software First save any data that has not yet been saved to the hard disk from the disk cache: 1 Launch a Web browser to the switch, and go to the Admin!File System display.
Chapter 1 Contivity 4500 Option Installation 31 Figure 7 Removing a Contivity 4500 hard disk drive Bo ot/ Ale Read rt/F y ail Drive 0 Drive 1 Insert and turn key, then remove hard disk by handle. CS460011A 3 Insert the replacement hard drive fully, and lock it by turning the key clockwise. Make sure the hard disk drive LED shows the proper drive number. 4 Replace the front bezel. 5 Reload the software on the disk.
Chapter 1 Contivity 4500 Option Installation 302283-D Rev 00
Chapter 2 Contivity 2500/2000/4000 Option Installation This section describes how to install or replace hardware components for the Contivity 2500, 2000, and 4000. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory.
Chapter 2 Contivity 2500/2000/4000 Option Installation Figure 8 Removing the Contivity 2500/2000/4000 front bezel Slide fingers behind front bezel and firm ly pull forward in the direction of arrows. Front Bezel The first few times you remove the front bezel it will be rather difficult to remove. This is because the ball stud and sockets are new. After a few times, removal is easier. Sliding the top cover back is optional; it allows you to get a better grip on the front bezel for removal.
Chapter 2 Contivity 2500/2000/4000 Option Installation 35 Removing the Contivity 2500/2000/4000 top cover Figure 9 shows you how to remove the top cover from the Contivity 2500/2000/ 4000. You must remove the cover to: • Install LAN, WAN, or hardware accelerator cards • Install additional memory Figure 9 Removing the Contivity 2500/2000/4000 top cover To remove the Contivity 2500/2000/4000 top cover: 1 Turn off the switch's power and unplug it.
Chapter 2 Contivity 2500/2000/4000 Option Installation Contivity 2500/2000/4000 system board layout Figure 10 shows the Contivity 2500/200 system board, in particular the DIMMs, option card slots, and the CPU cooling fan. The Contivity 4000 system board is similar, but has two CPUs as shown in Figure 11.
Chapter 2 Contivity 2500/2000/4000 Option Installation 37 Figure 11 Sample Contivity 4000 system board Installing Hardware Options for the Contivity VPN Switch
Chapter 2 Contivity 2500/2000/4000 Option Installation Installing Contivity 2500/2000/4000 LAN/WAN option cards Figure 12 shows you how to install LAN or WAN option cards into a Contivity 2500/2000/4000. You can use Slots 1 to 3 for any mix of LAN and WAN cards. Note that Slot 4 is not supported.
Chapter 2 Contivity 2500/2000/4000 Option Installation 39 To install an option card: 1 Turn off the switch and remove the power cord. 2 Remove the front bezel and top cover as shown in Figure 9. 3 Remove the filler panel screw and pull out the filler panel as shown in Figure 12. 4 Slide the option card into the intended slot. Make sure the card seats firmly and evenly in the card slot. If the card is not seated properly, it will not work. 5 Replace the card and screw.
Chapter 2 Contivity 2500/2000/4000 Option Installation Installing Contivity 2500/2000/4000 DIMMs Figure 13 shows you how to unlock a Dual Inline Memory Module (DIMM) in a Contivity 2500/2000/4000, and remove or install a DIMM. Install a DIMM in the next available slot (for example, if the DIMM #1 slot is populated, add the next DIMM to the DIMM #2 slot). Figure 13 Installing Contivity 2500/2000/4000 DIMMs Alignment keys To remove DIMMs, pull back locking lever and pull out DIMM.
Chapter 2 Contivity 2500/2000/4000 Option Installation 41 Replacing a Contivity 4000 power supply Figure 14 shows you how to replace a power supply for a Contivity 4000. Figure 14 Removing a Contivity 4000 power supply P re s s d o w n o n th e re le a s e b u tto n a n d re m o ve p o w e r su p p ly b y p u llin g h a n d le . To remove a Contivity 4000 power supply, remove the switch’s front bezel, then follow these steps: 1 Press the button down to turn off the power supply.
Chapter 2 Contivity 2500/2000/4000 Option Installation Replacing a Contivity 4000 disk drive To replace a Contivity 4000 disk drive, you must do the following: Software First save any data that has not yet been saved to the hard disk from the disk cache: 1 Use your Web browser to navigate to the switch, and go to the Admin!File System display. 2 Click the button “Prepare selected device for removal.
Chapter 2 Contivity 2500/2000/4000 Option Installation 43 Figure 15 Removing a Contivity 4000 hard disk drive D rive 0 D rive 1 In sert an d tu rn ke y, th en re m ove ha rd disk by h an dle. 2 Pull the handle to remove the hard disk drive. 3 Insert the replacement hard drive fully, and lock it by turning the key clockwise. Make sure the hard disk drive LED shows the proper drive number. 4 Replace the front bezel. 5 Reload the software on the disk.
Chapter 2 Contivity 2500/2000/4000 Option Installation Software Enable the switch by following these steps: 1 Use your Web browser to navigate to the switch, and go to the Admin!File System display. 2 Click on the drive and click the Enable button.
Chapter 2 Contivity 2500/2000/4000 Option Installation 45 Installing Contivity 2500/2000/4000 DIMMs Figure 16 shows you how to unlock a Dual Inline Memory Module (DIMM) and remove or install the DIMM in the next available slot (for example, if the DIMM #1 slot is populated, add the next DIMM to the DIMM #2 slot). Figure 16 Installing Contivity 2500/2000/4000 DIMMs Alignment keys To remove DIMMs, pull back locking lever and pull out DIMM.
Chapter 2 Contivity 2500/2000/4000 Option Installation To replace or change a DIMM, follow these steps. 1 Turn off the switch. 2 Remove the power cord. 3 Remove the front bezel as shown in Figure 8. 4 Remove the top cover as shown in Figure 9. 5 Press down the locking levers on both sides of the next available slot to allow the new DIMM to be inserted. 6 Pull the DIMM up to remove it from the slot. 7 Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys.
Chapter 3 Contivity 2600 Option Installation This section describes how to install or replace hardware components for the Contivity 2600. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory. Opening the Contivity 2600 To access the Contivity 2600 disk drive for system recovery operations, you must first remove the switch’s front bezel.
Chapter 3 Contivity 2600 Option Installation Removing the Contivity 2600 front bezel Note: Removing the front bezel on the Contivity 2600 system activates the chassis intrusion alarm whether or not the switch is turned on. This intrusion is reported to the system log file. You must remove the bezel to insert the recovery diskette. Note that you do not need to turn off the switch if you are only removing the front bezel. Figure 17 shows you how to remove the front bezel from the switch.
Chapter 3 Contivity 2600 Option Installation 49 The first few times you remove the front bezel it will be rather difficult to remove. This is because the ball studs and socket clips are new. After a few times, removal is easier. To remove the front bezel, you need a Phillips screwdriver. 1 Turn each of the two screws on the front bezel a quarter turn counter-clockwise. 2 Grip the two handles and pull the bezel towards you firmly to unsnap it from the chassis.
Chapter 3 Contivity 2600 Option Installation Figure 18 Removing the Contivity 2600 top cover Remove these four screws Boot/Ready Boot/Ready Alert/Fail Boot/Ready Slide cover forward and lift up CS260006A ➨ Slide the top cover forward approximately 1/4 inch, then lift the lid 2 to 3 inches and move it away from the chassis. Contivity 2600 system board layout Figure 19 shows the Contivity 2600’s system board, in particular the DIMMs, option card slots, and the CPU cooling fan.
Chapter 3 Contivity 2600 Option Installation 51 Figure 19 The Contivity 2600 system board DIMMs 1 2 CPU cooling fan 4 Option card slots 1 2 3 4 CS260008A Warning: Beware of danger if battery is incorrectly replaced. Replace with the same or an equivalent battery only, as recommended by the manufacturer’s instructions. Danger: In spite of the above warning, which is mandated for regulatory approval, you should not change the battery.
Chapter 3 Contivity 2600 Option Installation Installing LAN/WAN and hardware accelerator option cards Figure 20 shows you how to install LAN, WAN, or hardware accelerator option cards into the switch. You can use Slots 1 to 4 for any mix of LAN and WAN cards. Figure 20 Installing LAN/WAN or hardware accelerator cards Rear of unit Filler panel Option card Motherboard Option card slots CS2600017A To remove the front bezel and cover, you need a Phillips screwdriver. 1 Power off the switch.
Chapter 3 Contivity 2600 Option Installation 53 3 Remove the front bezel as shown in Figure 17. 4 Remove the top cover as shown in Figure 18. 5 Remove the filler panel screw and pull out the filler panel as shown in Figure 20. Caution: Be careful when inserting option cards into the Contivity 2600, as the slide-out tray is not fully supported once pulled out. You should support the back of the tray with your hand while inserting an option card. 6 Slide the option card into the intended slot.
Chapter 3 Contivity 2600 Option Installation Installing Contivity 2600 DIMMs Figure 21 shows you how to unlock a Dual Inline Memory Module (DIMM) and remove or install the DIMM in the next available slot (for example, if the DIMM #1 slot is populated, add the next DIMM to the DIMM #2 slot). Figure 21 Installing Contivity 2600 DIMMs Alignment keys To remove DIMMs, pull back locking lever and pull out DIMM.
Chapter 3 Contivity 2600 Option Installation 55 To replace or change a DIMM, follow these steps. 1 Turn off the switch. 2 Remove the power cord. 3 Remove the front bezel as shown in Figure 17. 4 Remove the top cover as shown in Figure 18. 5 Press down the locking levers on both sides of the next available slot to allow the new DIMM to be inserted. 6 Pull the DIMM up to remove it from the slot. 7 Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys.
Chapter 3 Contivity 2600 Option Installation 302283-D Rev 00
Chapter 4 Contivity 1600 Option Installation This chapter describes how Nortel Networks trained service personnel can change existing hardware configurations, including installing LAN and WAN cards and how to add memory for the Contivity 1600. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory.
Chapter 4 Contivity 1600 Option Installation Removing the Contivity 1600 front bezel You must remove the bezel to insert the recovery diskette. Note that you do not need to turn off the Contivity switch if you are only removing the front bezel. Figure 22 shows you how to remove the front bezel from the Contivity switch. Warning: When handling the Contivity switch outside of the rack-mount shelf, do not use the part labeled with the Nortel Networks logo and the LEDs as a handle.
Chapter 4 Contivity 1600 Option Installation 59 Removing the Contivity 1600 top cover To install LAN or WAN cards, or to install additional memory, you must remove the Contivity 1600’s front bezel and then the switch’s top cover. To remove the cover you need a Phillips screwdriver. Note: You do need to turn off the Contivity switch to remove the top cover. 1 Turn off the switch’s power and remove the power cord. Figure 23 shows how to remove the power cord from the Contivity switch.
Chapter 4 Contivity 1600 Option Installation Figure 24 Removing the Contivity 1600 top cover Remove these four screws Alert/Firm Boot/Ready Alert/Fail Boot/Ready Slide cover forward and lift up CS160003A 5 302283-D Rev 00 Slide the top cover forward approximately 1/4 inch, then lift the lid 2 to 3 inches, and move it away from the chassis.
Chapter 4 Contivity 1600 Option Installation 61 Contivity 1600 system board layout Figure 26 shows the Contivity 1600’s system board, in particular the DIMMs, option card slots, and the CPU cooling fan. Figure 25 Contivity 1600 system board Option card slots (only two are usable) DIMMs (1 and 2) 2 1 DIMM slots Not used 1 2 PCI slots CS160004A Warning: Beware of danger if the battery is incorrectly replaced.
Chapter 4 Contivity 1600 Option Installation Installing Contivity 1600 option cards This section shows you how to install LAN or WAN option cards in the Contivity 1600. 1 Turn off the switch. 2 Remove the power cord, as shown in Figure 26. Figure 26 Removing the Contivity 1600 power cord 100-2240VAC 2-1A 50-60Hz Power cable CS160009A 3 302283-D Rev 00 Remove the front bezel, as shown in Figure 22.
Chapter 4 Contivity 1600 Option Installation 63 4 Remove the top cover, as shown in Figure 23. 5 Remove the filler panel screw and pull out the filler panel, as shown in Figure 27. Figure 27 Installing Contivity 1600 LAN/WAN option cards Screwdriver slots Phillips screw Option card slot Option card Motherboard CS160020A 6 Slide the option card into the intended slot, as shown in Figure 28. Make sure the card seats firmly and evenly into the card slot.
Chapter 4 Contivity 1600 Option Installation Figure 28 Installing Contivity 1600 option cards Option card Option card slot Motherboard CS160019A 7 Replace the card and screw. 8 Replace the top cover. 9 Replace the front bezel. 10 Reconnect the power cord. 11 Turn on the switch.
Chapter 4 Contivity 1600 Option Installation 65 Installing Contivity 1600 DIMMs Figure 29 shows you how to unlock a DIMM and remove or install the DIMM in the next available slot (for example, if the DIMM # 1 slot is populated, than add the next DIMM to the DIMM # 2 slot). Figure 29 Installing Contivity 1600 DIMMs Alignment keys To remove DIMMs, pull back locking levers and pull out DIMM. To install DIMMs, pull back locking levers and push in DIMM.
Chapter 4 Contivity 1600 Option Installation To replace a DIMM, follow these steps. 1 Turn off the switch. 2 Remove the power cord as shown in Figure 23. 3 Remove the front bezel as shown in Figure 22. 4 Remove the top cover as shown in Figure 24. 5 Press down the locking levers on both sides of the DIMM as shown in Figure 29. 6 Pull the DIMM up to remove it from the slot. 7 Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys.
Chapter 5 Contivity 600 Option Installation This chapter describes how Nortel Networks trained service personnel can change existing hardware configurations, including installing LAN and WAN cards for the Contivity 600. Note: The expansion slot is renamed to Slot 2 by the Contivity 600 software. Warning: Wear an antistatic band when handling electronic components for the Contivity 600 to avoid damaging them.
Chapter 5 Contivity 600 Option Installation To install LAN or WAN cards you must: 1 Remove the power cable. 2 Remove all signal cables. 3 Remove the four screws on the bottom of the switch. 4 Slide the inner chassis out of the casing. 5 Unscrew the PCI interface bracket screw and remove the PCI interface card or blank PCI bracket. 6 Install a new PCI interface, being careful to completely press the card into the PCI connector on the mother board.
Chapter 5 Contivity 600 Option Installation 69 Opening the Contivity 600 To access the system, you must remove remove all cables, the power cord, and the bottom metal screws and pull the chassis from the rear. You need a Phillips screwdriver to access the system. 1 Unplug the switch’s power cord from the back of the chassis. 2 Unplug all the signal cables. 3 Turn the switch over to see the bottom of the box.
Chapter 5 Contivity 600 Option Installation 5 Firmly pull the chassis towards you to loosen it from the casing. You can gently shake it so that it slips outwards and into your hand or you can pull gently on the I/O expansion bay. Figure 31 shows how to remove the system from the chassis. Figure 31 Removing the system from the chassis l I/O EXPA NSION CONSOL E BAY LAN 1 FD LAN 0 RC DC INPU +12V-1. T 7A -12V-0.
Chapter 5 Contivity 600 Option Installation 71 Contivity 600 system board layout Figure 32 shows the Contivity 600 system board, in particular the option card slot, DIMM memory, and the CPU cooling fan. Figure 32 Contivity 600 system board Option card slot CPU cooling fan DIMM slot CS60005A Warning: Beware of danger if the battery is incorrectly replaced. Replace with the same or an equivalent battery only, as recommended by the manufacturer’s instructions.
Chapter 5 Contivity 600 Option Installation Installing Contivity 600 option cards This section shows you how to install LAN or WAN option cards in the Contivity 600. 1 Remove the blank PCI bracket by inserting a Phillips screw driver into the slot at the right of the blank PCI bracket and rotating the screw counter-clockwise. 2 Lift out the blank PCI bracket, and slide the replacement card into the intended slot. Note: Be careful not to bend the copper fingers in the slot.
Chapter 5 Contivity 600 Option Installation 73 Figure 33 Replacing the system into the chassis I/O EXPA NSION CONSOL E BAY LAN 1 FD LAN 0 RC DC INPU +12V-1. T 7A -12V-0.1 A +5V-10 A 75W MA X CS60004A 5 Replace the four Phillips-head screws to secure the bottom panel. 6 Reconnect the signal cables. 7 Reconnect the power cord to restart the Contivity 600. Memory option The Contivity 600 ships with 64 Mbits of memory installed. No additional memory can be installed.
Chapter 5 Contivity 600 Option Installation 302283-D Rev 00