User Guide

Table Of Contents
ME910G1 Hardware Design Guide
1VV0301593 Rev.15 Page
80 of 100 2022-08-23
Not Subject to NDA
Packaging Detail
Figure 37: Packaging detail
Moisture Sensitivity
The ME910G1 is a level 3 Moisture Sensitive Device, in accordance with the standard
IPC/JEDEC J-STD-020, it takes care of all related requirements for using this kind of
components.
Moreover, the customer must take care of the following conditions:
a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity (RH).
b) Environmental condition during production: 30°C / 60% RH according to IPC/JEDEC J-
STD-033A paragraph 5.
c) The maximum time between opening the sealed bag and the reflow process must be
168 hours if condition b) “IPC/JEDEC J-STD-033D paragraph 5.2” is respected
d) Baking is required if conditions b) or c) are not respected
e) Baking is required if the humidity indicator inside the bag indicates 10% RH
or more