Troubleshooting60
disconnected. A small overload could take a few minutes to
disconnect. The ProStar MPPT will attempt to reconnect the
load two (2) times. Each attempt is approximately 10
seconds apart. If the overload remains after two (2)
attempts, the load will remain disconnected until power is
removed and re-applied.
Solar Short Circuit
Charging Status LED: OFF. Solar input power wires are
short-circuited. Charging automatically resumes when the
short is cleared.
Battery Reverse Polarity
No LED indication, the unit is not powered. No damage to
the controller will result. Correct the miswire to resume
normal operation.
Load Short Circuit
Error status LED: Flashing red. Battery status LEDs: R/G-Y
sequencing. Fully protected against load wiring short-
circuits. After two (2) automatic load reconnect attempts (10
seconds between each attempt), the fault must be cleared
by removing and re-applying power.
High Solar Voltage Disconnect
Charging Status LED: R flashing. No battery status errors.
If the solar input open-circuit voltage (Voc) exceeds the 120
volt maximum rating, the array will remain disconnected
until the Voc falls safely below the maximum rating.
Remote Temperature Sensor (RTS)
Error status LED: Flashing red. Battery status LEDs: R/Y -
G/Y sequencing. A bad RTS connection or a severed RTS
wire has disconnected the temperature sensor during
charging. Charging automatically resumes when the
problem is fixed. To resume operation without an RTS,
disconnect all power to the ProStar MPPT and then
reconnect. If the controller is re-started with the failure still
present, the controller may not detect that the RTS is con-
nected, and the LEDs will not indicate a fault. A metered
model, an RM-1 meter, or MSView PC software