278
Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 600 V
Series F Continuous Flex Control Cables
High-Flex Cable Track Applications
600 V Unshielded, Multiconductor
UL TC-ER, PLTC
UL TFFN (18 – 16 AWG)
UL THHN (14 – 8 AWG)
CSA AWM I/II A/B FT4
CE LVD 73/23/EEC Amend.
93/68/EEC
Operating Temperature
-25°C to +90°C (static)
-5°C to +90°C (dynamic)
Conductor Color Coding
Red, blue, or black insulation*,
numbered
1 green/yellow green conductor
1 white-striped neutral
(12 conductors or greater,
except 14 AWG)
Materials
Stranded bare copper
conductors
PVC/nylon insulation
Black oil-resistant thermoplastic
elastomer jacket
Features
UL Sunlight Resistant
UL Oil Res. I/II
10x bend radius
Over 20 million rolling ex cycles
Tic-tock and twist test per
MIL-C-13777G
Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
FIT-600: Highly exible,
cross-linked elastomer
FIT-650: Chemical- and
temperature-resistant
fluoroelastomer
14 AWG (2.11 mm
2
)
Stranding: 105/34 (105 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Conductors
Nominal
Diameter
Jacket
Thickness
Black Insul. Blue Insul. Red Insul. Inch mm Inch mm
F14004KW F14004LW F14004RW 4 0.398 10.11 0.050 1.27
F14005KW F14005LW F14005RW 5 0.434 11.02 0.050 1.27
F14007KW F14007LW F14007RW 7 0.539 13.69 0.065 1.65
F14012KW F14012LW F14012RW 12 0.628 15.95 0.065 1.65
12 AWG (3.38 mm
2
)
Stranding: 168/34 (168 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Conductors
Nominal
Diameter
Jacket
Thickness
Black Insul. Blue Insul. Red Insul. Inch mm Inch mm
F12004KW F12004LW F12004RW 4 0.501 12.73 0.065 1.65
F12005KW F12005LW F12005RW 5 0.545 13.84 0.065 1.65
F12007KW F12007LW F12007RW 7 0.640 16.26 0.065 1.65
10 AWG (5.32 mm
2
)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Conductors
Nominal
Diameter
Jacket
Thickness
Black Insul. Blue Insul. Red Insul. Inch mm Inch mm
F10004KW F10004LW F10004RW 4 0.565 14.35 0.065 1.65
F10005KW F10005LW F10005RW 5 0.618 15.70 0.065 1.65
F10007KW F10007LW F10007RW 7 0.729 18.52 0.065 1.65
8 AWG (8.51 mm
2
)
Stranding: 168/30 (168 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm) PVC/0.006 (0.15 mm) nylon
Part No.
Conductors
Nominal
Diameter
Jacket
Thickness
Black Insul. Blue Insul. Red Insul. Inch mm Inch mm
F08004KW F08004LW F08004RW 4 0.740 18.80 0.065 1.65
* Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage