Instruction Manual

06
.
28
Han
Modular
Han
®
100 A Axial module
Features
Axial-screw termination
No special tools required
Connect PE contact with special cable shoe
Compatible to the Han
®
100 A module with crimp
terminal
Current carrying capacity
The current carrying capacity of the connectors is limited by the
thermal load capability of the contact element material including
the connections and the insulating parts. The derating curve
is therefore valid for currents which ow constantly (non-inter-
mittent) through each contact element of the connector evenly,
without exceeding the allowed maximum temperature.
Measuring and testing techniques according to
DIN EN 60 512-5-2
Operating current
Ambient temperature
24 B hoods/housings with 3 modules; wire gauge: 35 mm²
24 B hoods/housings with 3 modules; wire gauge: 25 mm²
Technical characteristics
Specications DIN EN 60 664-1
DIN EN 61 984
Approvals ,
Inserts
Number of contacts 2
Electrical data
acc. to EN 61 984 100 A 1000 V 8 kV 3
Rated current 100 A
Rated voltage 1000 V
Rated impulse voltage 8 kV
Pollution degree 3
Rated voltage
acc. to UL 600 V
Insulation resistance ≥ 10
10
Ω
Material polycarbonate
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Mechanical working life
- mating cycles ≥ 500
Contacts
Material copper alloy
Surface
- hard-silver plated 3 µm Ag
Contact resistance 0.3 mΩ
Screw terminal
- Wire gauge
1)
10 ... 38 mm²
- AWG 6 ... 2
- Hexagonal driver SW 4
- Stripping length 13 mm
- Tightening tourque
mm² 10 16 25 35
Nm 6 6 7 8
1) geometric wire gauge