Instruction Manual

06
.
78
Han
Modular
Han
®
High Density module
Features
• Suitable for D-Sub crimp contacts
• High contact density
• Using of guiding pins (male and female) is
recommended (see chapter 95).
Current carrying capacity
The current carrying capacity of the connectors is limited by the
thermal load capability of the contact element material including
the connections and the insulating parts. The derating curve
is therefore valid for currents which ow constantly (non-inter-
mittent) through each contact element of the connector evenly,
without exceeding the allowed maximum temperature.
Measuring and testing techniques according to
DIN EN 60 512-5-2
Operating current
Ambient temperature
➀
24 B hoods/housings with 6 modules; wire gauge: 0.5 mm²
turned contacts
➁
24 B hoods/housings with 6 modules; wire gauge: 0.5 mm²
stamped contacts
Technical characteristics
Specications DIN EN 60 664-1
DIN EN 61 984
Approvals
Inserts
Number of contacts 25
Electrical data
acc. to EN 61 984 4 A 50 V 0.8 kV 3
Rated current 4 A
Rated voltage 50 V
Rated impulse voltage 0.8 kV
Pollution degree 3
Rated voltage
acc. to UL < 30 V
Insulation resistance ≥ 10
10
Ω
Material polycarbonate
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Mechanical working life
- mating cycles ≥ 500
Contacts
Crimp terminal
- mm² 0.08 ... 0.52 mm²
- AWG 28 ... 20
turned contacts Performance level 1
as per CECC 75 301-802,
500 mating cycles,
10 days 4 mixed gas test -
IEC 60 512