Technische KennwerteFeatures Technical characteristics
Han
®
Shielded module
Data bus shielding separated from housing
Ideal for the transmission of very sensitive signals
(e.g. bus signals)
Specications DIN EN 60 664-1
DIN EN 61 984
Han
®
Module adapter
Number of contacts 20 + shield
Insulation resistance 10
10
Material Polycarbonate
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Mechanical working life 500 mating cycles
Shielded insert
Electrical data acc. to
DIN EN 61 984 4 A 32 V 0.8 kV 3
Rated current 4 A
Rated voltage
32 V
Rated impulse voltage 0.8 kV
Pollution degree 3
Material
- Insulator Liquid Crystaline Polymer
- Outer conductor Zinc alloy
Contact resistance 4 m
Limiting temperatures -40 °C ... +125 °C
Flammability acc. to UL 94 V 0
Outer surface nish Nickel
Cable diameter 5 ... 12 mm
Han
®
D-Sub crimp contacts
Crimp terminal
- mm² 0.08 ... 0.52 mm²
- AWG 28 ... 20
Turned contacts Performance level 1
Accessories
Crimp ange see page 06.98
Crimp ferrule see page 06.98
Cable clamp see page 06.98