UTG Series The plastic circular connector with metal locking UTG provides the complete answer to the need for economical lightweight and robust metal coupling Flammability rating UL94-V0 compliant Rapid and secure locking Locks with audible positive «click» Intermateable and interchangeable With UTO, UTP and UTS series Complete range of contacts Trim Trio contacts #16 Connection Technologies
UTG Series Layout Shell size Contact # 16 (Ø 1,6) Mixed power / signal versions 10 10-4 4 x #16 (Ø 1,6) 10-3 3 x #16 (Ø 1,6) Group C 250V 10-3W3 3 x #16 (Ø 1,6) 3 x #20 (Ø 1,0) 12 12-8 8 x #16 (Ø 1,6) 122G1 3 x #12 (Ø 2,4) 14 14-12 12 x #16 (Ø 1,6) 14-8 4 x #12 (Ø 2,4) 4 x #16 (Ø 1,6) 16 16-19 19 x #16 (Ø 1,6) 18 18-23 23 x #16 (Ø 1,6) 18-7 Group C 380V 7 x #16 (Ø 1,6) 2 18-7 34 2 x #12 (Ø 2,4) 5 x #16 (Ø 1,6)
UTG Series Shell size Contact # 16 (Ø 1,6) Mixed power / signal versions 20-28 28 x #16 (Ø 1,6) 20-20 20 x #16 (Ø 1,6) Group C 660V 20 22 22-35 35 x #16 (Ø 1,6) 24 24-48 48 x #16 (Ø 1,6) 24-7 7 x #8 (Ø 3,6) 2 x #16 (Ø 1,6) Contact identification positions shown are for mating face of pin contact connectors and wire face of socket contact connectors.
UTG Series Specifications Connector type / Part number Shell size 10 Cable plug Contacts number* Panel mounting receptacle Male insert Female insert Male insert Female insert 4 #16 UTG6104PN UTG6104SN UTG0104P UTG0104S 2 + ground #16 UTG6103PN UTG6103SN UTG0103P UTG0103S 3 #20 + 3 #16 UTG6103W3PN - - - 8 #16 UTG6128PN UTG6128SN UTG0128P UTG0128S 3 #12 UTG6122G1PN UTG6122G1SN UTG0122G1P UTG0122G1S 12 #16 UTG61412PN UTG61412SN UTG01412P UTG01412S 4#12 + 4 #16 - UTG614
UTG Series Dimensions Cable plug - UTG6 B ØC ØD Pin contact Socket contact B Shell size ØA±0.2 10 21.6 12 24.8 14 28.0 ØA B max Pin contact 23.9 / 26.75 31.8 31.2 18 34.3 31.8 / 33.0 31.8 / 35.3 20 37.5 47.0 24 50.1 ØC±0.15 ØD±0.15 10.9 12.2 23.9 16 22 Socket contact 23.9 / 29.0 24.9 31.8 13.8 15.1 17.0 18.3 19.9 21.5 22.4 24.0 25.6 27.2 28.5 30.4 31.7 33.5 26.2 ØE±0.2 19.
UTG Series Specifications Connector type / Part number Shell size Free hanging receptacle Contacts number* Male insert Female insert 4 #16 UTG1104P UTG1104S 2 + ground #16 UTG1103P UTG1103S 3 #20 + 3 #16 - UTG1103W3S 12 8 #16 UTG1128P UTG1128S 14 12 #16 UTG11412P UTG11412S 16 19 #16 UTG11619P UTG11619S 18 23 #16 UTG11823P UTG11823S 28 #16 UTG12028P UTG12028S 20 #16 UTG12020P UTG12020S 35 #16 UTG12235P UTG12235S 48 #16 UTG12448P UTG12448S 7 #8 + 2 #16 UTG1247P UTG1
UTG Series Dimensions Free hanging - UTG1 B ØD Pin contact Socket contact B Shell size ØA±0.2 10 19.5 ØA B max Pin contact Socket contact 24.3 / 27.6 12 23.5 14 27 16 30.0 18 33.3 31.7 / 34.0 20 36.5 33.3 / 34.3 22 39.5 24 42.1 ØD±0.15 15.0 19.0 31.7 24.3 22.2 25.3 24.3 / 30.4 28.5 25.9 34.9 31.7 38.
UTG Series Accessories Cable clamp Cable clamp for waterprotected (IP65) application Cable gland for waterprotected (IP65) application Part number Shell size Part number Shell size Part number Shell size UTG10AC 10 UTG10PG 10 UTG10ST 10 UTG12AC 12 UTG12PG 12 UTG12ST 12 UTG14AC 14 UTG14PG 14 UTG14ST 14 UTG16AC 16 UTG16PG 16 UTG16ST 16 UTG18AC 18 UTG18PG 18 UTG18ST 18 UTG20AC 20 UTG20PG 20 UTG20ST 20 UTG22AC 22 UTG22PG 22 UTG22ST 22 UTG24AC 24 UTG24PG 24
UTG Series Plastic protective cap for receptacle Gasket Part number Shell size Part number Shell size 8500-5586A 10 UTFD12B 10 8500-5587A 12 UTFD13B 12 8500-5588A 14 UTFD14B 14 8500-5589A 16 UTFD15B 16 8500-5590A 18 UTFD16B 18 8500-5591A 20 UTFD17B 20 8500-5592A 22 UTFD18B 22 8500-5593A 24 UTFD19B 24 9
UTG Series Tooling Standard contacts Contact size #20 1mm Part number RM/RC 24W3 RM/RC 20W3 RM/RC 18W3 SM 24W3S-(1) SC 24W3S-(1) SM 24WL3S-(2) SC 24WL3S-(2) SM/SC 20W3S-(1) SM/SC 20WL3S-(2) RM/RC 28M1RM/RC 24M9RM/RC 20M13RM/RC 20M12RM/RC 16M23RM/RC 14M30- SM/SC 24M1SM/SC 24ML1SM/SC 20M1SM/SC 20ML1SM/SC 16M1SM/SC 16ML1SM/SC 14M1SM/SC 14ML1SM/SC 16M11SM/SC 16ML11(1) contact reeled (2) loose contact Note: endurance of SHANDLES tool = 5 000 cycles. #16 1.
UTG Series Crimping One of the key factors which affects the performance of a connector, is the way contacts are terminated. Crimped connections are nowadays seen as the best solution to ensure quality throughout the lifetime of the product.
UTG Series Contacts Description The UTG series is delivered without contact (crimp version). When contacts are not loaded, this series offers the unique possibility to use the same contact in any layout as long as it receives the same active part size. Thus it is possible to buy only one contact reference and equip all connectors even if housings are different. The main benefit is the standardisation which means reduction of inventory cost.
UTG Series Contact plating selector guide As soon as you know what contact size you need, you next have to decide on which type to use. Souriau proposes mainly two different types of electrical contacts: - Machined - Stamped & formed Machined contacts are generally chosen for low quantities purpose as well as a better solution for power applications. Stamped & formed contacts offer the ability to be crimped automatically which makes them more suitable for high volume production applications.
UTG Series Contact selector guide Contact preloaded Electrical characteristics: contact resistance #20 Ø1mm #16 Ø1.6mm Available platings (contact preloaded) Machined < 4m Machined < 3m Min 0.4µ gold over 2µ Ni Contact supply separately Electrical characteristics: contact resistance #20 Ø1mm #16 Ø1.6mm Available platings (contact supply separately) Machined < 6m A 2µ Ni + 2µ Ag Stamped & formed < 15m J Gold flash over 2µ Ni Machined < 3m K Min 0.
UTG Series Crimp contacts Standard version Contact size Type Machined #20 Ø1 mm #16 Ø1.6 mm #8 Ø3.6 mm 26-24 0.13-0.20 Machined 22-20 RM24W3K RC24W3K (2) SM24WL30.32-0.52 22-20 Machined 20-18 0.50-0.93 Machined 30-28 0.05-0.08 Machined 26-24 0.13-0.2 Stamped & Formed 26-24 0.13-0.25 Machined 22-20 0.32-0.52 Stamped & Formed 22-20 0.35-0.5 Machined 20-16 0.52-1.5 18-16 0.8-1.5 Stamped & Formed 18-16 0.8-1.5 Machined 16-14 1.5-2.5 Machined 16-14 1.5-2.5 14 2.
UTG Series Crimp contacts First Mate Last Break contacts Contact size Type #16 Ø1.6 mm Longer male contact (+1mm) Machined #16 Ø1.6 mm Shorter female contact (-0.7mm) Machined Wire size Color band Part number mm² Male 0.05-0.08 26-24 0.13-0.2 22-20 0.32-0.52 - 20-16 0.52-1.5 16-14 1.5-2.5 16-14 1.5-2.5 RM28M1GE1□ RM24M9GE1□ RM20M13GE1□ RM20M12GE1□ RM16M23GE1□ RM14M50GE1□ RM14M30GE1□ 30-28 0.05-0.08 26-24 0.13-0.
UTG Series #16 coaxial contacts Coaxial contact range We provide 2 types of coaxial contacts suitable for 50 or 75, coaxial cable or twisted pair cable. Monocrimp coaxial contact • The monocrimp one-piece coaxial contacts offer high reliability plus the economic advantage of a 95% reduction in installation time over conventional assembly methods. • This economy is achieved by simultaneously crimping both the inner conductor and outer braid or drain wire.
UTG Series PCB contacts PCB contacts PCB soldering UTG range can be carried out with a wave soldering process, but not reflow soldering process. All high temperature processes are prohibited. Contact size Type #20 Ø1mm Part number Plating Male Female Short version RMW50A7K RCW50A7K Long version RMW5016K RCW5016K Short version RM20M12E8K RC20M12E8K Long version RM20M12E83K K #16 Ø1.6mm RC20M12E83K K RC20M12E84K Exemple: RM50A7K - Size #20, Short version, male.
UTG Series Fibre optic contacts Description Size 16 Fibre optic contacts for TRIM TRIO® connectors Size 16 Fibre optic contacts are optical contacts designed for the integration of optical links in all TRIM TRIO® cable connectors. The Fibre optic contacts are designed to accommodate: • Plastic Optical Fibre (POF) 1 mm core and 2.2 mm jacket • Plastic Clad Fibre (PCF) 230µm core and 2.
UTG Series Fibre optic contacts Ordering information POF Contacts (Plastic Optical Fibre) Male contact ..................................................... RMPOF1000 Female contact ............................................... RCPOF1000B POF Contact (Plastic Optical Fibre) SPECIFIC TOOLING LIST - can be ordered only separately STANDARD TOOLING KIT - P/N 80MS0004 The standard tooling kit is made of the part numbers below that can be ordered separately as well.
UTG Series #16 coaxial contacts Coaxial cable - Contact monocrimp and multipiece Cable type Impedance Ø over jacket Contact type inch mm Ø over dielectric inch mm Inner cond size Ø outer braid Ext. Ø mm inch mm RG161/U 75 0.09 2.29 0.057 1.45 RG179A/U 75 0.105 2.67 0.063 1.6 0.3 0.084 2.13 max RG179B/U 75 0.105 2.67 0.063 1.6 0.3 0.084 2.13 max RG187/U 75 0.11 2.79 max 0.06 1.52 0.3 RG188/U 50 0.11 2.79 max 0.06 1.52 0.51 0.078 1.98 max RG174/U 50 0.
UTG Series #16 coaxial contacts Twisted cable - Contact monocrimp and multipiece Cable type Inner Contact AWG type cond Ø over jacket (single wire) Ø outer braid Inner cond size inch mm Stranded definition Ext. Ø mm inch mm Male contact kit for coaxial cable Female contact kit for coaxial cable 2#24 stranded mil w 16878 type B 24 0.049 1.24 max 7/.008 - - RMDXK10D28 RCDXK1D28 2 #24 solid mil-w-76 type LW 24 0.047 1.12 max 1/.0201 - - RMDXK10D28 RCDXK1D28 26 0.043 1.
UTG Series Twisted pair cable multipiece contact cabling Cable reference Contact type Male contact Female contact Crimp tool Die set Stop bushing - - Cable strip length A B C Inner conductor crimp g dim t dim Braid crimp g dim t dim 2#24 stranded mil w 16878 type B 2 #24 solid mil-w-76 type LW 2 #26 stranded mil w 76 type LW or mil w16878 type B & E Multi piece 2 #28 solid mil-w-81822/3 RMDXK10D28 RCDXK1D28 M10S1J See assembly notice twisted pair 1/.
UTG Series #16 coaxial contacts Twisted pair cable monocrimp contact cabling Contact type g dim t dim S80 SL105 4.7 6.1 4.32 1.30 to 1.12 1.4 to 1.22 2.97 to 2.84 3.07 to 2.9 20218204 S80 SL105 3.94 6.1 3.16 1.30 to 1.17 1.4 to 1.22 2.97 to 2.84 3.07 to 2.79 #30 solid S83 SL105 4.7 6.1 4.06 1.22 to 1.12 1.35 to 1.22 2.97 to 2.84 3.12 to 2.95 #26 7/.0063 S80 SL105 4.7 6.1 4.06 1.30 to 1.17 1.4 to 1.22 2.97 to 2.84 3.07 to 2.9 4.7 6.1 4.06 1.22 to 1.17 1.35 to 1.
UTG Series Multipiece male contact with coax cable Cable reference RG161U RG179 RG187U RG188/U RG174/U RG178A/U RG196U Hyring complementary compoments Contact Outer contact crimp tool Inner contact crimp tool Crimp tool M10S1J Crimp tool M10S1J Die set Stop bushing Die set Cable strip length Stop bushing A B C 4.37 7.95 15.88 4.37 7.95 15.88 4.37 7.95 15.88 4.37 7.95 15.88 4.37 7.95 15.88 7.54 9.12 17.53 7.54 9.12 17.53 - 4.37 7.95 15.88 - 4.37 7.95 15.
UTG Series #16 coaxial contacts Multipiece female contact with coax cable Cable reference RG161U RG179 RG187U RG188/U RG174/U RG178A/U RG196U Hyring complementary compoments Contact Outer contact crimp tool Inner contact crimp tool Crimp tool M10S1J Crimp tool M10S1J Die set Stop bushing Die set Stop bushing YOC074 S26D2 Female: S221 YOC074 + RMDXB0553 RCDXK1D28 SL471 21-598 B - C 11.13 11.13 11.13 11.13 11.13 11.13 11.13 - 4.37 11.13 - 4.37 11.
UTG Series Coax cable with monocrimp contact cabling Cable reference Male contact Female contact CDC PIN22939200 RMDX6046D28 Crimp tool Cable strip length Inner conductor crimp g dim t dim Braid crimp Die set Stop bushing A B C g dim t dim RCDX6016D28 S80 SL105 4.19 5.97 8.51 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.84 CDC PIN22939200 RMDX6046D28 RCDX6016D28 S87 SL105 5.08 6.35 8.89 1.30/1.17 1.40/1.22 2.77/2.64 3.02/2.
UTG Series Glossary of terms • Clearance Per the IEC 60664-1 it is the shortest distance between two conductive parts even over the air. • CTI (Comparative Tracking Index) The CTI value is commonly used to characterize the electrical breakdown properties of an insulating material. It allows users to know the tendency to create creepage paths. This value represents the maximum voltage after 50 drops of ammonium chloride solution without any breakdown.
UTG Series 29
UTG Series 30
UTG Series 31
Stage - Light Industry Building automation & control Off road - Mining Railway www.souriau-industrial.com contactindustry@souriau.com Connection Technologies 32 Medical WINDUTGO02EN © Copyright SOURIAU 2013 - All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.