Product Manual

Operation Using the Sprayer
23
Drain cap
Filter
bowl
6. Ensure tank
flushed
Ensure tank is flushed of all chemicals from prior uses.
- Chemicals can interact dangerously when mixed, and residue chemicals are also a
health hazard.
See the “Flush Sprayer” information in Clean sprayer and decontaminate after use
section of this manual. The tank can be drained using either the drain cap, or
opening the ball valve and removing the filter bowl.
7. Fill tank
Add pesticide to tank through fill cap:
a) Confirm the chemical/water dilution ratios specified on the chemical label.
b) Determine chemical and water volumes needed for the planned application,
taking into consideration that maximum tank capacity is 200 gallons.
Note: Only purchase and mix as much chemical as you need for the
planned application in order to minimize chemical over application and
the need for storing unused chemicals.
c) Add chemical to the tank through the fill cap.
If the chemical is not pre-mixed, add water and pesticide concentrate in the order
prescribed on the label.
8. Ensure
chemical
mixed
Ensure chemical is thoroughly mixed in tank.
- Stirring device should be made of metal or plastic, non-chemical absorbing
material, and then properly cleaned and stored after use.
9. Replace fill cap
Replace fill cap and tighten securely.