Product Manual

Assembly
19
Step 8: Check and test completed assembly.
WARNING
Check and test completed assembly
Serious injury could result from chemical leaks if sprayer is improperly
assembled or the design of the sprayer is modified.
Follow the steps below to ensure the sprayer is properly assembled. Never
modify the sprayer design.
1. Check assembly
Check assembly to assure the sprayer is properly assembled and in safe
working condition:
a) Check that the gun clip screws are tight, hose clamps are secure, and tank
straps are properly fastened.
b) While it is unlikely that factory assembled components become loose, they
should also be checked to make sure they are tight.
2. Test with water
Test the system for leaks with water:
a) Fill the tank with water.
b) Connect the wire harness to the pump power cord and turn the remote
switch ON. The pump is an "on demand" pump. When turned on, the
pump will prime itself, and then turn off. When the gun trigger is
squeezed, the pump will automatically start.
c) Operate the spray gun by squeezing the gun trigger.
d) Check for leaks throughout the system. If a leak is detected, fix the leak
and re-test the system with water.