Product Manual

Operation - Using the Broadcast Kit (continued)
27
B. Ensure uniform coverage
To ensure proper coverage, the height of the broadcast nozzles should be 24"-
48" inches from the ground. Using both broadcast nozzles, the spray pattern is
40 feet. However, the spray pattern should be overlapped 36 inches. Use the
tables in Appendix A to determine what speed to drive your vehicle for the
desired application rate.
C. Begin to spray
Open the boom valve and turn the remote switch ON to begin spraying.
8. Leaving
unattended
If the sprayer must be left unattended at any time:
a) Disconnect power to the sprayer.
b) Relieve system pressure by depressing the gun trigger.
c) Turn off the vehicle. Set brake or block the wheels.
9. Discontinue use if
clogged or
inoperative
If the sprayer becomes clogged or inoperative during use, discontinue use
immediately.
- DO NOT attempt to service while chemicals are in the sprayer and power is
connected.
- Return to service area to review instructions for troubleshooting before
attempting to service.
Correct
Incorrect
12” Overlap