Product Manual
Machine Component Identification – Item #165913H.1 (cont’d)
9
REFERENCE GUIDE
Reference 1 – Circuit Breakers
This belt driven single-phase generator has 2,
20 amp (A) push to reset circuit breakers to
protect against electrical overloads.
Reference 2 –120V Receptacle
The generator has an end cover with one duplex
(two receptacles in a common housing)
receptacle and one locking device receptacle.
The duplex is a 120-volt (V) 20 amp (A) straight
blade receptacle, National Electrical
Manufacturer’s Association (NEMA) number 5-
20R. This receptacle accepts NEMA plug
numbers 5-15P and 5-20P. Each receptacle on
the duplex is capable of drawing 20A.
Reference 3 – 240V Receptacle
The locking device is a 240V 20A NEMA L6-20R
receptacle. This receptacle accepts a NEMA
plug number L6-20P.
Reference 4 – Ground Screw
Ground the generator via the ground screw, to a
copper pipe or rod that is driven into moist soil.
Reference 5 – 7/8” diameter
shaft
The shaft is 1.50” long and has a 3/16” keyway.
Reference 6 – Mounting feet
Use these three locations to bolt the generator
head in place.
Reference 7 – Fan Vents
Never block the vent slots or insert objects
through the slots.