Problem
Solution
Motor will not start
SOLUTION: A,B, M, N, O
Low/Surging pressure or no water flow
SOLUTION: C,D,E,F,G,H
No chemical injection
SOLUTION: I,J,K,L
Cause
Solution
A- Tripped GFCI cord
Reset GFCI cord
B- Tripped motor relay
Reset motor
C- Insufficient water supply
See water supply section of this manual
D- Plugged pump inlet filter
See maintenance section of this manual
E- Wrong nozzle
Make sure high-pressure nozzle is being used
F- Plugged nozzle
Remove nozzle, check for blockage
G- Worn nozzle
Replace nozzle
H- Leak in pressure hose
Replace pressure hose
I- Wrong nozzle
Make sure chemical nozzle is being used
J- Back pressure from extra-long discharge hose
Try shorter hose
K- Leak in chemical siphon hose
Replace hose use hose clamps if necessary
L- Chemical strainer not submerged
Make sure strainer is completely submerged
M- Tripped circuit breaker
Make sure breaker is rated to 120V/20A (990990 only)
Make sure breaker is rated to 230V/30A (990991 only)
N- Extension cord too long
Use extension cord with an appropriate rating for distance
O- Debris in flow switch
Clean flow switch