Product Manual

11
Outdoor Use Only
Select a suitable outdoor location:
Where it will NOT be exposed to rain, snow, or
direct sunlight.
Where no flammable vapors, dusts, and gases
are present.
At least 7 feet away from combustible materials
At least 20 feet from the home, away from
windows, vents and air intakes, to allow proper
ventilation.
Away from other heat-generating equipment.
Away from dusty/dirty conditions.
Positioning:
The compressor should be mounted on a dry,
firm, and level surface. It must sit level and be
stabilized so it will not slide or shift during
operation.
Situate so there is adequate pulling room for
starting the engine using the recoil starter.
Attempting to pull at an odd angle could rip off grip
cord and/or cause muscular injuries to the
operator.
Airflow:
The location should allow for adequate,
unobstructed airflow for cooling and combustion
air.
Do not allow debris to accumulate or block
airflow.
Do not operate with a tarp, blanket, or cover
surrounding the machine.
Do not place any objects against or on top of the
unit.
Exhaust:
WARNING: Exhaust modification hazard
Never attempt to attach ductwork to the muffler system
to allow for installation inside an enclosure. This could
cause heat build-up and increased exhaust back-
pressure, resulting in possible exhaust leakage or
damage to the compressor.
Place the unit so that the exhaust fumes will not
be directed towards people or building air intakes.
Keep a fire extinguisher rated “ABC” nearby
which is properly charged. Be familiar with its use.
Provide battery-operated or battery back-up type
carbon monoxide alarms in any structure that is in
close proximity to the running compressor.
Do not install in small, enclosed areas without an
ample circulation of supply air.
DANGER: Carbon monoxide hazard
Exhaust fumes from the engine contain carbon monoxide
(CO), a poisonous gas you cannot see, smell, or taste. The
CO generated by the engine can rapidly accumulate, even
in areas that appear to be well ventilated, resulting in
dangerous and fatal concentrations within minutes. NEVER
run air compressor inside any enclosed or semi-enclosed
spaces, including homes, garages, basements, sheds,
boxes, pick-up truck beds, RVs, or boats. These spaces
can trap poisonous gases, EVEN if you run a fan or open
windows. If you start to feel sick, dizzy, or weak while using
the air compressor, shut off the engine and get to fresh air
RIGHT AWAY. See a doctor. You may have carbon
monoxide poisoning.
Ideal operating temperatures:
40 and 100F (4 and 37C).
Operating Limitations:
15F (-9C) or above 125F (52C).
If temperatures consistently drop below 32 F (0C),
store inside a heated building. If this is not possible,
protect the safety/relief and drain valves from freezing.
Note: In frequently humid areas, moisture may form in
the pump and produce sludge in the oil, causing parts
to wear out prematurely. Excessive moisture is likely
to occur if unit is stored in an unheated area subject to
large temperature changes.
Two signs of excessive humidity are external
condensation on the pump when it cools down and a
“milky” appearance in pump oil.
Install Spark Arrestor (if Required)
Equip engine with spark arrestor if machine will be used
near any ignitable forest, brush, or grassy land. (See
engine Owner’s Manual provided to determine if the
engine is already equipped.) Make sure you comply with
applicable local, state, and federal codes.
Installing Air Discharge Hose/Piping
If installing discharge piping you must:
Adhere to all local building codes.
Use discharge piping of the same diameter as the
compressor discharge connection.
Use pipe, tube, hose, or distribution components
rated for use with compressed air and maximum
pressure of this compressor.
Use a properly rated flexible connection between
the tank and discharge piping.
WARNING: Burst hazard
Do not use plastic (PVC) pipe, rubber hose, copper, or
lead-tin soldered joints anywhere in the compressed air
system.