Product Manual

Installation (continued)
11
Step Four: Check and test completed assembly.
WARNING
Check and test completed assembly
Serious injury could result from chemical leaks if pump is improperly assembled or the design
of the pump is modified.
Follow the steps below to ensure the pump is properly assembled. Never modify the pump
design.
1. Check
assembly
Check assembly to assure the pump is properly assembled and in safe
working condition:
2. Test with
water
Test the system for leaks with water:
a) Fill the tank with water.
b) The pump is an “on demand” pump. When turned on, the pump will
prime itself, then turn off once reaching pressure. When the flow
continues, the pump will automatically re-start.
c) Check for leaks throughout the system. If a leak is detected, fix the leak
and re-test the system with water.