Owner's Manual

45
angle offset. After input the known distance, press [ENT] to enter the
interface of Offset (dist1)-Prism :
Offset (dist1)-Prism
SD
HR 200°5421
m
T.HMeas
HD
Mode
VD
After measuring, press [Enter] to enter the result interface:
Offset (dist1)-Result
N -10.998
HR 200°5421
m
Next P
E -4.201
Save
Z 0.190
Display the coordinates or offset point. Pressing [Next P] to
measure next point; press [Save] to save the coordinates of offset
point; press [ESC] to exit.
8.3 Offset (Dist2)
It is specifically useful when the measured point is exactly on
the line of the two measurable points, as well as the distance between
measured point and the two measuring point is known.
Offset distance
OSD
A1
A0
Prism P0
Prism P1
Instrument center
Station
Firstly, input the offset distance. If the directions of P1-A0 and
P0-P1 are same, the distance value is positive, otherwise it is
negative.
In the menu of Offset, select 3. Offset (Dist2) to enter the
interface of Offset (Dist2):