Owner's Manual

62
9.2.3 Resection
Set up instrument on a new point, and measure at most 5 known
points to calculate the coordinates of this new point, the measurement
of resection is as following:
Resection by distance measurementMeasure at least two
known points.
Resection by angle measurementMeasure at least three known
points.
1) Enter the second interface of staking out and press
[F2](Resection);
S.O
1.PolarCoord.Meas
2/2
2.Resection
P2
2) Input the new point name (Pt.n),code and target height (I.H);
New Pt.
Pt.n:
B.S
Enter
Code:
T.H->
1
1
1.000
m
3) Press [F1](Input) to input point 1(Here, you can retrieve
points) and press [F4];
Resection
NO.1
Num.
List
B.S
Enter
Pt.n:
1
[Enter]
Resection
NO.1
Coord.
List
Input
Enter
Pt.n
1
4) If the point doesnt exist in this file, tips None Pt.n. You