Installation Instructions

Installation of the aerator and Bio-Kinetic system should take place when the Singulair Green system is ready for
start-up. Refer to the Bio-Kinetic System Installation instructions for additional details regarding the installation of the
Bio-Kinetic system. Your delivery truck driver should have instructed the contractor or owner to contact your o󰀩ce and
make arrangements for equipment installation to occur after the home is occupied and the sanitary sewer is in use.
The Bio-Kinetic system is installed in the nal clarication chamber of the Singulair Green tank. This unique device
accomplishes tertiary treatment, ow equalization and, if required by local regulations, e󰀪uent disinfection and dechlorination
in one compact assembly. The Bio-Kinetic system is recommended for use in direct o󰀨-lot discharge applications and any
other application where extremely high quality e󰀪uent is desirable. Installation of the Bio-Kinetic system can take place
as soon as the tank is ready for storage or immediately after the tank is installed in a prepared excavation.
Drain and ll valves built into the Bio-Kinetic system allow it to be installed within the Singulair Green tank any time before
or after the tank has been set. This allows faster Singulair Green system installation and less time at the installation site.
When installing the Bio-Kinetic system before tank delivery, make sure the tank is stored in a level position to avoid stress
on the receiving ange, the Bio-Kinetic discharge ange or to prevent damage to the outer chamber lter media.
BIO-KINETIC
®
SYSTEM PRE-INSTALLATION CHECKLIST
All chambers of the Singulair Green tank should be full to the ow line with clean hold down water as soon as the tank is
placed in the excavation and backlling is complete. When the owner calls for start-up, ask him to check the liquid level in
the Singulair Green system. If the liquid level has not reached the outlet invert, have the owner add clean water until full.
The service vehicle should be fully stocked, including the Singulair Tool Kaddy, Bio-Kinetic lubricant,
Blue Crystal disinfecting tablets and Bio-Neutralizer dechlorination tablets.
Make sure the proper model of Bio-Kinetic system for the installation is in the service vehicle. The
Bio-Kinetic system may be supplied with or without Blue Crystal and Bio-Neutralizer chemical feed systems.
Therefore, check your order and Distributor Service and Warranty Record Card carefully to be sure you have selected
the proper Bio-Kinetic system with the correct service cover, ow distribution deck and feed tube(s) and that it is properly
labeled for the correct model Singulair Green system.
PREPARING THE SINGULAIR GREEN TANK
1. The Bio-Kinetic system mounting riser should be used
for access to the clarication chamber. Additional
extension risers may be added as necessary to reach
nished grade.
2. The Bio-Kinetic system should only be installed in a
mounting riser with a sealed access cover above it.
All mounting risers and covers must be in place before
backlling the tank to prevent ll material from entering
the Singulair Green tank. The top of each access cover
must be located 3" to 6" above nished grade. Check
to be sure that a pretreatment tee is installed in the
opening in the pretreatment/aeration chamber wall.
3. Check to be sure that a Bio-Static sludge return
is properly installed in the opening in the aeration/
clarication chamber wall.
4. The Singulair Green tank should be lled with clean
water. The water should be free of dirt, mud, leaves, grit,
oils or other materials that might possibly interfere with
operation of the system. The tank should be lled with
BIO-KINETIC SYSTEM
AUTOMATIC DRAIN AND FILL VALVES
SINGULAIR GREEN
®
BIO-KINETIC
®
WASTEWATER TREATMENT SYSTEM
INSTALLATION OF THE BIO-KINETIC
®
SYSTEM