Use and Care Manual

BIO-KINETIC
®
WASTEWATER TREATMENT SYSTEM
CLEANING AND DISASSEMBLY INSTRUCTIONS
FOR THE BIO-KINETIC
®
SYSTEM
EQUIPMENT REQUIRED FROM THE
BIO-KINETIC SYSTEM TOOL KADDY
water hose and spray nozzle
Bio-Kinetic system universal tool
rubber gloves
safety face shield or goggles
ratchet drive and
7
/
16
" socket
A fresh water supply and sewer drain are required for
cleaning the Bio-Kinetic system.
1. Remove the Bio-Kinetic system from the service
container. Rinse the container and lid. Rotate the four
locking lugs to the outboard position on the Bio-Kinetic
system. Remove the gasketed discharge flange
assembly from the flow deck and rinse it with water.
2. Grasp the top flange of the system with one hand
and insert the disassembly tool beneath each of
the strap handles on the flow deck. Pull up on the
disassembly tool to remove the flow deck and internal
system components from the contact chamber and set
aside. Use the water hose and spray nozzle to wash
the inside of the contact chamber.
3. Use the water hose and spray nozzle to wash off the
filter media. Continue spraying until all sludge and
wastewater have been flushed from the media. Invert
the filter assembly and flush accumulated material
from the baffled perimeter settling zone. Inspect the
perimeter settling zone to be certain that it is totally
clean. Check the flow equalization ports to be sure
they are clean and unobstructed.
4. Wash off any debris that has accumulated on the
surface of the flow distribution deck and baffle wall
shroud. Lay the assembly down on its side and
remove the four wing nuts on the bottom. Remove and
wash the bottom deck plate.
CAUTION: Do not break or damage the molded
plastic tabs on the edge of the bottom deck plate.
Do not remove the remaining deck plates at this time.
Stand the assembly upright and lift up on the flow
distribution deck to separate it from the baffle wall
shroud and deck plates. You may find it helpful to hold
the baffle shroud between your feet when lifting up on
the flow deck.
NOTE: The through bolts will be removed from the shroud
and deck plates when the flow deck is lifted off the baffle
CLEAN BAFFLED PERIMETER SETTLING ZONE
LAY ASSEMBLY ON SIDE