Operating Manual 5301 Series Load Pins
Operating manual 5301 Series Load Pins Safety note Use for intended purpose The force transducers in model series F5301 are intended for the measurement of static and dynamic tensile or compressive force. These devices have been constructed and tested in accordance with the safety regulations for electronic measuring equipment. Any other usage is deemed to be incorrect . The transducers can only be guaranteed to operate correctly and safely if the information in the operating instructions is complied with.
Operating manual 5301 Series Load Pins Maintenance The force transducers in the F5301 model series are maintenancefree. During welding work the transducer must be bypassed with a copper 2 wire (min. 50 mm ) so that welding current does not flow through the transducer and weld the force introduction points. Ambient temperature The temperature range of -20°C to +80°C that is specified in the data sheet applies with regard to deployment.
Operating manual 5301 Series Load Pins Fig. 1 Name plate Type Model Output Power Supply S# Serial Number UB+ Pin assignment – power supply + 0V/S- Pin assignment – power supply - / output - S+ Pin assignment – output + Tension Compression 4 NOSHOK, Inc. • 1010 West Bagley Road, Berea, OH 44017 • Ph: 440.243.0888 • Fax 440.243.3472 • www.noshok.
Operating manual 5301 Series Load Pins General Installation Guidelines • The loads acting upon the force transducer must be as exact as possible in the load direction. • Torsion and lateral force must be avoided. The transverse loads and side forces also include the relevant components of the measured variables, which may be introduced at an incline. • Torsional moments, off-centre loads and lateral loads or side forces cause measuring errors and can permanently damage the transducers.
Operating manual 5301 Series Load Pins Please note the following: • Always use shielded, low-capacity measuring cables (all tecsis cables meet these requirements, see chapter 10.1). • Do not route the measuring cable parallel to high-voltage current and control cables. • Avoid leakage fields from transformers, motors and contactors. • The transducer, the amplifier and the display unit must not have multiple grounds. Attach all equipment to the same protective conductor.
Operating manual 5301 Series Load Pins overload 4 12 (125% nominal load) 3,8 20 21 short circuit cable break [mA] With activating the check relay a fixed signal jump of 8 mA will exceed the overload limit in every working condition. The measurement’s upper limit of 20 mA however will never be reached. This makes the checking of the signal jump possible.
Operating manual 5301 Series Load Pins Mini-Hirschmann connector G4a1MMT Mini-Hirschmann connector G4a1MMT UB UB / S+ S+ 1 3 1 3 2 2 0V / S- 0V / S- 940E05 940E02 Cable output Cable output UB / S+ brown 0V / S- blue UB brown S+ black 0V / S- blue Shield Shield 940E03 940E06 8 NOSHOK, Inc. • 1010 West Bagley Road, Berea, OH 44017 • Ph: 440.243.0888 • Fax 440.243.3472 • www.noshok.
Operating manual 5301 Series Load Pins Power supply: UB+ Power supply: 0V/UB-/S- mV/V Output (4 – wire) 0…20mA (3 – wire) 4…20 mA (2 – wire) 0…10 VDC (3 – wire) Colour coding cable 1 1 1 1 brown 3 3 3 3 blue Supply Relay: (UR) Supply Relay: (0V) 2 2 4 3 withe black / blue Signal: S+ 4 4 - 4 black Signal: S_ 2 - - - white housing housing housing housing Schirm Schirm Switch: 2 switching outputs CANopen n- switching Round connector M12x1, 5-polig p- switching 4 5
Operating manual 5301 Series Load Pins Technical data Mo d el Nominal force Fnom 5301 5 / 10 / 20 / 30 / 50 / 100 / 200 kN Force limit Breaking limit Accuracy Relative backlash width (Hysteresis) Creeping, 30 min. at Fnom Nominal temperature range Storage temperature Temperature influence - Meas.range - Null signal Transverse force action 150 % Fnom > 300 % Fnom < 2 % of F.S. and < 0,5 % of F.S. < 0,5 % of F.S. and <0,2 % of F.S. 0,1 % of F.S. -4 ... 176 °F (-20 … 80 °C) -40 ...
Operating manual 5301 Series Load Pin Load pin, dimensions Version up to 10 kN Axle bracket in acc.with DIN 15 058 (not included in scope of delivery) Version from 20 kN Plug M12x1 For two-sided measuring axle mounting the following applies: Bohrung-/Bolzenpaarung: H9/f9 ** Other bolt diameters available on request, drill hole tolerance H9 CORPORATE HEADQUARTERS NK095301TM INCORPORATED 1010 West Bagley Road · Berea, Ohio 44017 440-243-0888 · Fax 440-243-3472 E-mail: noshok@noshok.com Web: www.