5 Connecting and Managing Cables
5.1 Connecting the Ground Cable
Once the AirStrand 1300 is securely attached on the strand it is advisable to connect an approved
ground cable.
Connect the ground cable after attaching a grounding lug to the ¼-20 threaded hole on the top of the
AirStrand 1300 body, as shown below:
Figure 10: Ground Cable Connection
Note: Cutting the Ground cable to the required length and crimping the grounding lug is
performed by the Installer.
Note: The threaded ¼-20 ground hole is bare metal and needs no preparation.
Note: The minimum cable gauge to be used for the ground wire is 9 AWG.
5.2 1300 Interface Connection
Danger: Hazardous voltage! Before working, ensure that the power is off, prior to
performing any connections (shut Circuit breaker). AC Power Rating 40-90VAC
Note: The circuit breaker should be at least 6 A.
5.2.1 Connecting the Shielded CATV Cable
Note: The shielded CATV cable supplies both power and data and is fed from an external isolated
transformer.
Once the AirStrand 1300 is securely attached on the strand the installer should connect the shielded
CATV cable terminated with an RF connector to the F-type connector (factory installed) connected to
the unit’s connecting outlet.
1. Connect the shielded CATV cable terminated with an RF connector to the F-type connector
connected (factory installed) to the unit’s connecting outlet.
Note: Supplied with F-type connector adapter but other connectors (i.e. stinger) are available if
required.