Installation Guide

AirStrand 1300 Installation Guide
DUG01370-SP Airspan Commercial and Internal Use 26
Figure 11: Connect Shielded CATV Cable
Note: When securing the cable make sure there is no tension on the connector so that it is easy to
disconnect and re-connect for future maintenance actions.
Caution: Take care not to over tighten the F-type RF connector. The connector should be
tightened to a nominal torque maximum of no more than 1.6NM/14.1600 in/lbs.
5.2.2 Weather-proofing the CRTV RF Connection
Weather-proofing of all the connections is recommended. This is done with a layer of self-amalgamating
tape followed by an over layer of PVC tape.
Figure 12: Weather-proof the CRTV RF Connection
Note: It is good practice to weather-proof the connections of both the RF connection and the GPS
connection.
Verify the RF connector is completely weather-proof.
5.2.3 Connector Replacement
In the event the RF connector needs replacement use two (2) wrenches so as to prevent accidentally
loosening the F-type connector adaptor (factory installed) connected to the unit’s connecting outlet.
Figure 13: Use 2 Wrenches to Loosen