3.1.2 One of the Sensor Units has the DSRC module enabled which should
be mounted facing the main street with minimum field of view
obstruction in order to provide the best possible range for V2I
communication.
3.1.3 Example location: on the luminaire arm or traffic light mast arm.
Height is more important than having the SU in the center of the
approach, consult NoTraffic team on best possible location if not clear
prior to installation.
3.1.4 Mount Astro-Brac per manufacturer's instructions.
3.2 AC cable pull and termination
3.2.1 Pull an AC cable (mains power – 110VAC) to the SU installation
location.
3.2.2 Follow instructions from manufacture (brown in diagram is live, blue is
neutral) to terminate provided connector to AC cable:
https://ch.schurter.com/content/download/1739414/32059397/version
/2/file/0115.0074_B_Mounting%20Instruction.pdf
8