Owner's Manual
Document No. 610-00-0303 Rev E.
COPYRIGHT © 2019 NOVAERUS US, INC.
5
CAUTION: To reduce the risk of electric shock, this equipment has a grounding type plug that has a
third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug
does not fit into the outlet, contact qualified personnel to install the proper outlet. Do
not alter the plug in any way.
5. Technical Specifications
a. Dimensions: 5.2” w x 11.1” h x 4.3” d
b. Weight: Approx. 7.6 lb.
c. Power Requirements: 120 VAC, 60 Hz, 0.08 A
d. Fuse Specification: 125 VAC, 3 Amps, Listed
e. Mounting: Wall mountable, countertop or stand-alone
f. Fan Air Flow: 50 ft
3
/min
g. Shipping / Storage Conditions: 5°C-50°C, Maximum 95% Relative Humidity
h. Operating Conditions: 10 - 35°C, 10 - 75% Relative Humidity, 2000m
6. Instructions For Use
The product should be placed in a dry location and connected to a suitable grounded outlet. The
product is intended to be either placed on a flat surface or wall mounted. If wall mounting is
desired, please follow the instructions provided in the Wall Mounting Instructions included in this
document. Once the product is installed, turn the power switch to the on position. The device is
now operating.
7. Wall Mounting Instructions
The mounting of this product shall be conducted by a trained service person that is experienced
with the proper use of standard installation tools such as a drill, screw driver, tape measure and
level.
The product can be wall mounted using suitable fasteners for your wall type. Fix the screws
horizontally with a spacing of 2-1/2”. Leave the screw head protruding no more than 0.5 “ from the
wall for hanging. Ensure screws are tightly secured into the wall and a solid connection is made
between the screws and the unit. Ensure the product is level. Follow these instructions depending
upon mounting surface:
For hollow wall construction studded with metal or wood framing and sheathed with Drywall,
Plaster, or Plywood, an appropriate hollow wall such as a #10 re-usable anchor.
Each of the two reusable anchors must be rated for a 20.0 lbs. rating minimum and be the
appropriate size for the sheathing thickness. Use #10 size minimum.