Protect 900 User Manual (NV900) Novaerus, US Inc. 35 Melrose Pl. Stamford, CT 06902 Phone: 1.866.515.5181 www.novaerus.com Document No.
Table of Contents 1. Intended Purpose ���������������������������������������������������������������������������������������������� 3 2. Labeling Symbols ���������������������������������������������������������������������������������������������� 3 3. Classification of Equipment ���������������������������������������������������������������������������� 4 4. Warnings ������������������������������������������������������������������������������������������������������������ 4 5.
1. Intended Purpose The intended purpose of the Novaerus Protect 900 (NV900) is to improve the quality of air. Please read and follow all instructions in this manual. 2. Labeling Symbols Symbol Meaning Caution, Consult User’s Manual Caution, High Voltage Date of Manufacture Manufactured for or by Serial Number This product has been tested by UL to nationally recognized safety and sustainability standards. On (Power) Off (Power) Slow Fan Speed (Speed 1) High Fan Speed (Speed 2) Document No.
Accompanying documents must be consulted Indicates the temperature limits to which the medical device can be safely exposed. Indicates the range of humidity to which the medical device can be safely exposed. 3. Classification of Equipment Item Classification Protection of Harmful Ingress of Water IPX0 (No protection, indoor use only) Mode of Operation Continuous Oxygen Rich Environments Not intended for oxygen rich environments 4.
continued… CAUTION: Do not open the tamper proof screws on the casing of the unit. No serviceable parts are contained within. CAUTION: No modification of this equipment is allowed. Do not modify this equipment without authorization of the manufacturer. CAUTION: Do not position the equipment where it is difficult to operate the power switch. CAUTION: For continued protection against risk of fire, replace the fuse with the same type and rating, Listed, 120 Vac, 3 Amps.
5. Technical Specifications Wall mountable, countertop with table stand or mounted on portable high tower stand, supplied with 6.6 ft power cord Fan Air Flow Volume: Electrical Rating: SPEED I: 40 dB SPEED II: 45 dB Single Phase, 100-120 VAC, 60 Hz Fuse Rated at 120 VAC, 3 Amps, Listed Power Consumption: Maximum 14W Construction and Color: Precision-cut fabricated metal casing in a white anti-bacterial powder coat finish Dimensions: 14.4" (h) × 14.4" (w) × 4.
. Instructions for Use The product should be placed in a dry location and connected to a suitable grounded outlet. The product is intended to be wall mounted or placed on a stand. Please follow the wall mounting instructions included in this document. Once the product is installed, turn the power switch to the on position. The device is now operating and the blue light will be illuminated. The product includes a fan speed switch to allow the product to be set on a slow or high speed.
For Concrete or Masonry Wall Construction Use purposed 3/16" (4. 8 mm) concrete screws. Each of the two screws must be rated for 20.0 lb (9.1 kg) minimum. Typical drill size is 5/32" (4 mm) for the 3/16" (4.8 mm) concrete screw. Follow manufacturer’s instructions and recommendation for drill depth for screws being used.
. Service and Maintenance Instructions Clean the body of the Protect 900 regularly to prevent dust from collecting. 1. Wipe away dust from the body of the device with a soft dry cloth. 2. Clean the air outlet with a soft dry cloth. Air Intake Screen Cleaning of the air intake screen is recommended monthly. To clean the air intake screen, use a standard vacuum cleaner brush or compressed air in an open ventilated area to blow the dust off the screen. Use a bowl of soapy water to hand wash the scrim.
The metal frame grid should be facing towards the rear of device as shown in the image below. An additional screen has been provided for each unit to allow for rotation during the cleaning process. The Protect 900 unit should not be operated without the air intake screen in place. Service Do not open the tamper proof screws on the casing of the unit. No serviceable parts are contained within. The units should be opened by qualified Novaerus personnel only. 10.
12. APPENDIX A. Guidance and Manufacturer’s Declarations Table 201 – Guidance and manufacturer’s declaration – electromagnetic emissions – for all equipment and systems Guidance and manufacturer’s declaration – electromagnetic immunity The Protect 900 is intended for use in the electromagnetic environment specified below. The customer or the user of the Protect 900 should assure that it is used in such an environment.
Table 202 – Guidance and manufacturer’s declaration – electromagnetic immunity – for all equipment and systems Guidance and manufacturer’s declaration – electromagnetic immunity The Protect 900 is intended for use in the electromagnetic environment specified below. The customer or the user of the Protect 900 should assure that it is used in such an environment.
continued… Power frequency (50/60 Hz) magnetic field EN 610004-8 30 A/m 30 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. NOTE: Ut is the a.c.mains voltage prior to application of the test level. Document No.
Table 203 – Guidance and manufacturer’s declaration – electromagnetic immunity – for equipment and systems that are not life-supporting Guidance and manufacturer’s declaration – electromagnetic immunity The Protect 900 is intended for use in the electromagnetic environment specified below. The customer or the user of the Protect 900 should assure that it is used in such an environment.
continued… 28 V/m, 217 Hz PM 1970 MHz 9V/m, 217 Hz PM 5240 MHz 9 V/m, 217 Hz PM 5500 MHz 9 V/m, 217 Hz PM 5785 MHz 5240 MHz 9 V/m, 217 Hz PM 5500 MHz 9 V/m, 217 Hz PM 5785 MHz than the compliance level in each frequency range b. Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations.
Table 204 – Recommended separation distances between portable and mobile RF communications equipment and the equipment and system – for equipment and systems that are not life supporting Recommended separation distances between portable and mobile RF communication equipment and the Protect 900. The Protect 900 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.