User's Manual
Table Of Contents
- Safety Precautions
- Regulatory Compliance FCC
- Manual Overview
- Introduction
- Technical Specifications
- Physical Interfaces
- Enabler II-G Mounting Reference
- Pin Orientation Reference
- Connectors
- I/O Signal Connector on the Enfora Enabler II-G Module
- Antenna
- Control Connector Signal Descriptions and Functions
- Input Power
- Ring Indicate
- Radio Power/Reset
- Serial Interface (9 Pin I/F) (See table in section 6.5.1 I/O Connector Pin Assignments)
- General Purpose Input/Output Interface (GPIO)
- Analog-To-Digital Input
- Digital-To-Analog Output
- Handset Microphone Input
- Handset Speaker Output
- Headset Microphone Input
- Headset Speaker Output
- Audio Design Note
- Subscriber Identity Module (SIM) Carrier
- Modes of Operation
- SIM Operation
- Software Interface
- Setup and Initialization
- General Setup
- HyperTerminal Configuration for Enabler II-G
- Initialization (AT Command Interface)
- Initial Response to the AT Command
- Sending an Initialization String to the Enfora Enabler II-G Module
- Setting Up the Communication Mode for the Enfora Enabler II-G Module
- Querying the Status of the Enfora Enabler II-G Module
- Setting Module Reporting Parameters for GSM and GPRS
- GSM/SMS Examples
- GPRS Packet Examples
- General Setup
- Integration and Testing
- APPENDIX A - Warranty Repair and Return Policy
- APPENDIX B - Regulations and Compliance
- GCF Approval (Formerly FTA)
- Electromagnetic Compatibility (EMC) and Safety Requirements
- EMC/Safety Requirements for the USA
- Human Exposure Compliance Statement
- Compliance with FCC Regulations
- Unintentional Radiators, Part 15
- Intentional Radiators, Part 24
- Instructions to the Original Equipment Manufacturer (OEM)
- Nationally Recognized Testing Laboratory (NRTL) Approval
- EMC/Safety Requirements for the Countries of the European Union (EU)
- EMC/Safety Requirements for Other Countries
- APPENDIX C - Glossary and Acronyms
- APPENDIX D – Tables And Figures
- APPENDIX E - Contacting Enfora
Integration Guide
Version 1.07
GSM0100PB001 Page 19 1.07 - 1/9/04
5.4 Transmit Power
Enfora Enabler II-G module Power Class Transmit Power
1900 MHz
1800 MHz
GSM Power Class 1 1-W conducted power maximum (30
dBm +/- 2 dB), measured at the
antenna port
850 MHz
900 MHz
GSM Power Class 4
2-W conducted power maximum
(33 dBm +/- 2 dB),
measured at the antenna port
5.5 Receiver Sensitivity
Enfora Enabler II-G module Sensitivity Mode
1900 MHz
1800 MHz
-108 dBm (typical)
GPRS Coding Scheme 1 (CS1)
900 MHz
850 MHz
-108 dBm (typical)
GPRS Coding Scheme 1 (CS1)
5.6 Radio Power Down
Input has internal pull-up. Low is modem OFF. High (or open) is modem ON.
Radio Power Down Parameter/Conditions MIN TYP MAX UNIT
VIL
Input Voltage - Low
-0.5 0.9 Vdc
VIH
Input Voltage - High
2.0 3.4 Vdc