User's Manual

LPP0108IG001 52 Version - Preliminary – 06/20/08
7.12. BCI Command Parameters - Appendix 2
Table of BCI command parameters relating to per-unit calibration and system-level configuration.
Calibration is required on every module.
Configuration is required once and all modules configured likewise.
Recommend leave all other parameters at default values.
Command Parameter Factory
Production
Calibration
Customer
Calibration
Factory
Configuration
Customer
Battery
Configuration
Customer
Charger
Configuration
AT$BCIVSF <num> X Opt.
<offset> X Opt.
AT$BCIISF <adc_num> X Opt.
<adc_offset> X Opt.
<pre_chgireg> X Opt.
AT$BCIAVG <alfaV> X Opt.
<alfaT> X Opt.
<alfaI> X Opt.
<sampling> X Opt.
AT$BCIDEL <cmd> Opt. Opt.
<id> Opt. Opt.
AT$BCIOFF <flag> Opt. Opt.
AT$BCICHG#
<type> X
<ci_chgireg> X
<ov_thr> X
< id_low> X
<id_high> X
AT$BCIBAT#
<type> X Opt.
<T1> X
<T2> X
<T3> X Opt.
<chg_again_thr> X
<cv_chgvreg> X Opt.
<id_low> X
<id_high> X
AT$BCIMAP#
<#_ci_elements> X Opt.
<10%> X Opt.
<20%> X Opt.
<30%> X Opt.
<40%> X Opt.
<50%> X Opt.
<60%> X Opt.
<70%> X Opt.
<80%> X
<90%> X
<100%> X
AT$BCIPCT#
<10%> X Opt.
<20%> X Opt.
<30%> X Opt.
<40%> X Opt.
<50%> X Opt.
<60%> X Opt.
<70%> X Opt.