User's Manual Part 1

36 Specifications Expedite G301 OEM Module Specifications
Revision 1.8 P/N 90023363
Figure 6 Power Enable-On, ATH4 Command Shutdown
Figure 7 Power Enable On, Power Enable Shutdown
Baseband Connector on Expedite
The following sections detail the baseband connector. All baseband connectors meet UL 94V0
flammability requirements.The specifics of the connector are provided below.
PWRON
PUL_PWRENb
PWR_LATCH
(internal signal)
VCC_HOST
(internal
MDM_RDY
Modem not on or Software Initializing
Modem Initialized and Application
Ri
ATH4 Command
Issued
H
L
H
L
H
L
H
L
H
L
t
MODEMOFF
(De-registering
From
PWRON
PUL_PWRENb
PWR_LATCH
(internal signal)
VCC_HOST
(internal power)
MDM_RDY
Modem not on or Software Initializing
Modem Initialized and Application Running
t
MODEMOFF
H
L
H
L
H
L
H
L
H
L
* ATH4 Command Not Issued (Method Not Preferred)