commands when the rover station is receiving corrections from multiple base stations. See Section
5.2, Satellite-Based Augmentation System (SBAS) on Page 78 for more information on SBAS.
All PSRDIFFSOURCE entries fall back to SBAS (even NONE) for backwards compatibility.
At the base station it is also possible to log out the contents of the standard corrections in a form that is
easier to read or process. These larger variants have the correction fields broken out into standard
types within the log, rather than compressed into bit fields. This can be useful if you wish to modify
the format of the corrections for a non-standard application, or if you wish to look at the corrections
for system debugging purposes. These variants have "DATA" as part of their names (for example,
RTCADATA1, RTCMDATA1, CMRDATAOBS, and more). Refer also to the OEMV Firmware
Reference Manual, which describes the various message formats in more detail.
4.4 Using the DL-V3
A group is a set of logs for the receiver. The default software configuration for group information
includes a group named default. A powerup group must be created to take advantage of the automatic
functionality. Refer to the DL-V3 Firmware Reference Manual for more information on groups,
commands and logs specific to the DL-V3.
Upon acquisition of coarse time, if a group named powerup exists, the DL-V3 executes the group
automatically.
The FRESET command allows you to reset the DL-V3 to its factory default settings. SITEDEF logs,
refer to the DL-V3 Firmware Reference Manual, contain site record information. For example:
#SITEDEFA,COM1,0,61.0,FINESTEERING,1420,316947.028,00180020,e40c,2678;
0,"","DL-V3ii",0,0.000000000,"",1420,1420,316890.000,316935.000,00000000,0
*c56c1a5d
4.4.1 Log Data from a Site to a File
Consider the case when you want to log data at a site and append a filename and other information.
The following steps apply to a base or rover site. For the base, you only need to log one file per
session.
There is no need to continually start and stop logging if you are using post-processing
software, where it is dealt with automatically.
To log a group and update the site information
1. Select the Group
2. Edit the Site
3. Start the Data Logging