User's Manual

36 SMART-MR10 User Manual Rev 0B
Chapter 3 Operation
Figure 8: Basic Differential Setup
Reference Description
1 SMART-MR10 receiver
2 User-supplied 5A fuse
3 User-supplied power supply, for example a battery
4 User-supplied device to COM1
5 User-supplied radio device to COM2
6 User-supplied PC/laptop, for setting up and monitoring, to COM1
System biases can introduce errors. Refer to the NovAtel web site at http://www.novatel
.com/support/
for more information. In most cases you need to provide a data link between the base station and rover
station (two NovAtel receivers) in order to receive corrections. The application of SBAS corrections
to a single receiver are an exception to the base/rover concept. Generally, a link capable of data
throughput at a rate of 9600 bits per second, and less than 4.0 s latency, is recommended.
Once your base and rover are set up, you can configure them as outlined in the configuration examples
in 3.3.1, Base Station Configuration on page 37 and 3.3.2, Rover Station Configuration on page 38.
Base
Rover
+
-
4
+
-
1
2
1
2
3
3
5
5
6
COM1
COM2
COM1
COM2